3-195
Confidential
(7) Remove the Retaining ring E3 from the Feed roller and remove the Feed roller bushing TR.
Fig. 3-287
(8) Remove the Lift spring from the Hook of the Lift lever A.
(9) Remove the Feed roller from the Main body in the directions of the arrows 9a, 9b, and 9c
in this order.
Fig. 3-288
Retaining ring E3
<Right side>
Feed roller
Feed roller bushing TR
Lift lever A
Lift lever A
Hook
Lift spring
8
9a
9c
9b
<Front side>
Main body
Feed roller
Содержание DCP-L8400CDN
Страница 38: ...2 8 Confidential 2 2 2 Scanning part Fig 2 4 Right side Left side Face up Document scanning feed path ...
Страница 249: ...3 85 Confidential 3 Remove the ADF spring from the Upper ADF chute Fig 3 95 ADF spring Upper ADF chute ...
Страница 277: ...3 113 Confidential 9 35 LCD 1 Remove the LCD from the Control panel ASSY Fig 3 145 Control panel ASSY LCD ...
Страница 391: ...5 7 Confidential Common to first and second side Fig 5 1 ...