2-89
Confidential
4.2.3
No paper feeding from MP tray
< User Check >
- Check if the paper is loaded all the way into the MP tray.
- Check that too much paper is not loaded in the MP tray.
- Check if the machine is used with the MP tray support and MP flap are in closed state.
- Check if the thickness of the paper is 60 to 163 g/m
2
.
- Check whether the paper tray 1 or T2 paper tray unit is specified for the paper feeding tray.
- Fan the stack of paper well and reinsert the papers into the MP tray.
- Clean the MP paper pick-up roller.
- Check whether the paper tray 1 is closed correctly.
Step
Cause
Remedy
1
MP paper empty acutuator A
ASSY/B coming off
Re-assemble the MP paper empty
acutuator A ASSY/B.
2
Connection failure of the main
motor harness
Reconnect the main motor harness.
3
MP roller holder ASSY
installation failure
Check the installation of the MP roller
holder ASSY and install it correctly.
4
Connection failure of the MP
paper empty/registration front
sensor PCB harness
Reconnect the MP paper empty/
registration front sensor PCB harness.
5
MP paper pick-up roller worn out
Replace the PF kit MP.
6
MP paper empty acutuator A
ASSY/B failure
Replace the MP paper empty acutuator A
ASSY/B.
7
MP paper empty/registration
front sensor failure
Replace the MP paper empty/registration
front sensor PCB ASSY.
8
Main motor failure
Replace the process drive unit.
9
Paper feed related gear
damaged
Replace the main drive unit.
10
Fuser unit damaged
Replace the fuser unit.
11
Main PCB failure
Replace the main PCB ASSY.
Содержание DCP-L8400CDN
Страница 38: ...2 8 Confidential 2 2 2 Scanning part Fig 2 4 Right side Left side Face up Document scanning feed path ...
Страница 249: ...3 85 Confidential 3 Remove the ADF spring from the Upper ADF chute Fig 3 95 ADF spring Upper ADF chute ...
Страница 277: ...3 113 Confidential 9 35 LCD 1 Remove the LCD from the Control panel ASSY Fig 3 145 Control panel ASSY LCD ...
Страница 391: ...5 7 Confidential Common to first and second side Fig 5 1 ...