3-137
Confidential
9.46 Main PCB ASSY
(1) Disconnect the twenty five Connectors (CN2, CN3, CN4, CN5, CN6, CN8, CN9, CN10,
CN12, CN13, CN14, CN15, CN16, CN17, CN18, CN19, CN21, CN30, CN40, CN42,
CN43, CN44, CN46, CN47 and CN49) and three Flat cables (CN7, CN31 and CN45) from
the Main PCB ASSY.
Fig. 3-187
Note: Backup of machine information
Before starting disassembly work, back up the machine information and user setting
information.
(Refer to
“1.3.13 Backup of machine information (Function code 41)” in Chapter 5
After replacing the PCB, restore the backup data to a new PCB.
Note:
- After disconnecting flat cables, check that each cable is not damaged at its end or
short-circuited.
- When connecting flat cables, do not insert them at an angle. After insertion, check
that the cables are not at an angle.
Main PCB ASSY
CN41
CN39
CN38
CN37
CN33
CN32
CN28
CN27
CN20
CN3
CN4
CN5
CN2
CN6
CN7
CN21
CN8
CN10
CN12
CN11
CN9
CN13
CN22
CN14
CN15
CN26
CN17
CN18
CN19
CN31
CN30
CN45
CN40
CN47
CN46
CN44
CN43
CN42
CN16
CN49