3-110
Confidential
9.34 Panel PCB Unit
(1) Disconnect the Flat cable (CN4) of the Panel PCB unit and release the wiring.
Fig. 3-139
■
A4 model
(2) Remove the three Taptite cup B M3x10 screws from the LCD hold plate.
(3) Release the four Hooks and remove the LCD hold plate from the Control panel ASSY.
Fig. 3-140
CN4
Panel PCB unit
Flat cable
Control panel ASSY
Taptite cup B M3x10
Hook
Hook
LCD hold plate