3-112
Confidential
(4) Remove the four Taptite cup B M3x10 screws and remove the Panel control PCB shield
plate cover from the Control panel ASSY.
Fig. 3-143
(5) Release the Lock and disconnect the Flat cable (CN1) of the Panel PCB unit.
(6) Disconnect the Flat cable (CN2) from the Panel PCB unit. (Model with NFC only)
(7) Remove the Panel PCB unit from the Control panel ASSY.
Fig. 3-144
Taptite cup B M3x10
Panel control PCB
Control panel ASSY
shield plate cover
Control panel ASSY
CN1
Panel PCB unit
CN2
Lock
Flat cable
Flat cable
Flat cable
Содержание DCP-L8400CDN
Страница 38: ...2 8 Confidential 2 2 2 Scanning part Fig 2 4 Right side Left side Face up Document scanning feed path ...
Страница 249: ...3 85 Confidential 3 Remove the ADF spring from the Upper ADF chute Fig 3 95 ADF spring Upper ADF chute ...
Страница 277: ...3 113 Confidential 9 35 LCD 1 Remove the LCD from the Control panel ASSY Fig 3 145 Control panel ASSY LCD ...
Страница 391: ...5 7 Confidential Common to first and second side Fig 5 1 ...