9.70 Blower
(1) Release the wiring of the Blower.
(2) Remove the Blower from the Main frame R ASSY.
Fig. 3-271
Harness routing: Refer to
Assembling Note:
When assembling the Blower, be sure to assemble it in a way that the label side faces out.
Label
<Right side>
Main frame R ASSY
Blower