2-58
Confidential
Error code 6A00
Electric discharge that may be caused by dirt on the corona wire of the drum unit was detected.
<User Check>
• Slide the green tab of the drum unit to left and right for two to three times to clean the corona wire.
• Clean the electrode of the drum unit. (Refer to
• Replace the drum unit.
Error code 6F00
Detected that supply power is unstable. (less than 100 times)
<User Check>
• Turn the power switch OFF and then back ON again.
• Use a noise filter on the power supply.
Error code 7000
After the registration rear sensor detects paper pass, the eject sensor does not detect paper pass.
<User Check>
• Remove the jammed paper.
Step
Cause
Remedy
1
Dirt on the electrodes of the
machine
Clean the electrodes of the machine.
(Refer to
.)
2
Dirt on the high-voltage power
supply PCB terminal
Clean the high-voltage power supply PCB
terminal.
3
High-voltage power supply PCB
failure
Replace the high-voltage power supply
PCB ASSY.
4
Main PCB failure
Replace the main PCB ASSY.
Step
Cause
Remedy
1
The power supply waveform is
incorrect
Install a voltage stabilizer in the power
supply part.
Step
Cause
Remedy
1
Foreign object inside the machine
Remove the foreign object.
2
Eject actuator coming off or caught
in some sections of the machine
Reattach the eject actuator.
3
Fuser cover attachment failure
Reattach the fuser cover.
4
Connection failure of the eject
sensor PCB harness
Reconnect the eject sensor PCB harness.
5
Damaged fuser drive gear 64R/
36R
Replace the fuser drive gear 64R/36R.
6
Damaged gears in the paper
feed drive system
Replace the frame L unit.
7
Eject sensor failure
Replace the eject sensor PCB ASSY.
8
Fuser unit failure
Replace the fuser unit.
9
Main PCB failure
Replace the main PCB ASSY.
Содержание DCP-2537DW
Страница 50: ...2 10 Confidential MP models Fig 2 6 Feed from MP tray Eject to back side Back side Front side ...
Страница 51: ...2 11 Confidential 2 2 2 Scanner part Fig 2 7 Document feed path ...
Страница 159: ...3 2 Confidential 2 PACKING Fig 3 1 Option carton Carton Polystyrene pad ASSY Spacer carton Option carton TBOX ...
Страница 240: ...3 83 Confidential 9 25 Filter 1 Release the Hook to remove the Filter from the Air duct Fig 3 79 Hook Filter Air duct ...
Страница 300: ...5 28 Confidential Print adjustment test pattern Fig 5 11 ...
Страница 311: ...5 39 Confidential Print pattern Fig 5 16 W 100 K 1 K 100 Total Lattice K 5 ...
Страница 316: ...5 44 Confidential Test pattern Fig 5 19 ...
Страница 332: ...5 60 Confidential ...