9.11 ADF unit
(For models with ADF)
9.11.1 ADF unit
(1) Remove the ADF FFC holder from the Panel flat cable, the First side CIS flat cable, and the
Second side CIS flat cable.
(2) Remove the Taptite bind B M4x12 (black) screw from the Hinge ASSY L.
Fig. 3-28
Fig. 3-29
Assembling Note:
• Attach the Panel flat cable, the First side CIS flat cable, and the Second side CIS flat
cable to the ADF FFC holder as shown in the figure below.
Hinge ASSY L
Taptite bind B M4x12 (black)
ADF FFC holder
First side CIS flat cable
Panel flat cable
Second side CIS flat cable
First side CIS flat cable
Second side CIS flat cable
ADF FFC holder
Panel flat cable
Содержание DCP-2537DW
Страница 50: ...2 10 Confidential MP models Fig 2 6 Feed from MP tray Eject to back side Back side Front side ...
Страница 51: ...2 11 Confidential 2 2 2 Scanner part Fig 2 7 Document feed path ...
Страница 159: ...3 2 Confidential 2 PACKING Fig 3 1 Option carton Carton Polystyrene pad ASSY Spacer carton Option carton TBOX ...
Страница 240: ...3 83 Confidential 9 25 Filter 1 Release the Hook to remove the Filter from the Air duct Fig 3 79 Hook Filter Air duct ...
Страница 300: ...5 28 Confidential Print adjustment test pattern Fig 5 11 ...
Страница 311: ...5 39 Confidential Print pattern Fig 5 16 W 100 K 1 K 100 Total Lattice K 5 ...
Страница 316: ...5 44 Confidential Test pattern Fig 5 19 ...
Страница 332: ...5 60 Confidential ...