2-69
Confidential
Error code BB00
A white level not within the standard was scanned when function code 55 was executed.
Error code BC00
When scanning the fax, white or black correction data for the second side CIS was not within
the correct range (second time).
Error code BD00
A black level not within the standard was scanned when function code 55 was executed.
Step
Cause
Remedy
1
Dirt on the second side
document hold
Clean the second side document hold.
2
Dirt on the white tape
Clean the white tape.
3
First side CIS unit failure
Replace the first side CIS unit.
4
Second side CIS unit failure
Replace the second side CIS unit.
5
Second side document hold
failure
Replace the ADF unit.
6
White tape failure
Replace the document scanner unit.
7
Main PCB failure
Replace the main PCB ASSY.
Step
Cause
Remedy
1
Incorrect correction data for
second side CIS unit
Execute “Acquire white level data
2
Dirt on the white tape on the
second side document hold
Clean the white tape on the second side
document hold.
3
Damaged second side CIS flat
cable
Replace the second side CIS flat cable.
4
Second side CIS unit failure
Replace the second side CIS unit.
5
White tape failure
Replace the ADF unit.
6
Main PCB failure
Replace the main PCB ASSY.
Step
Cause
Remedy
1
Dirt on the second side
document hold
Clean the second side document hold.
2
Dirt on the white tape
Clean the white tape.
3
First side CIS unit failure
Replace the first side CIS unit.
4
Second side CIS unit failure
Replace the second side CIS unit.
5
Second side document hold
failure
Replace the ADF unit.
6
White tape failure
Replace the document scanner unit.
7
Main PCB failure
Replace the main PCB ASSY.
Содержание DCP-2537DW
Страница 50: ...2 10 Confidential MP models Fig 2 6 Feed from MP tray Eject to back side Back side Front side ...
Страница 51: ...2 11 Confidential 2 2 2 Scanner part Fig 2 7 Document feed path ...
Страница 159: ...3 2 Confidential 2 PACKING Fig 3 1 Option carton Carton Polystyrene pad ASSY Spacer carton Option carton TBOX ...
Страница 240: ...3 83 Confidential 9 25 Filter 1 Release the Hook to remove the Filter from the Air duct Fig 3 79 Hook Filter Air duct ...
Страница 300: ...5 28 Confidential Print adjustment test pattern Fig 5 11 ...
Страница 311: ...5 39 Confidential Print pattern Fig 5 16 W 100 K 1 K 100 Total Lattice K 5 ...
Страница 316: ...5 44 Confidential Test pattern Fig 5 19 ...
Страница 332: ...5 60 Confidential ...