2-71
Confidential
Error code D800
An error occurred while initializing the touch panel.
Error code E000
An error occurred in the ROM check sum.
Error code E100
Program error
<User Check>
• Install the latest main firmware.
Error code E500
An error occurred during access to the DRAM in the main PCB ASSY.
Error code E600
Write error in the EEPROM of the main PCB ASSY
Error code E701
System error in the flash ROM
Error code E702
Read error in the flash ROM
Step
Cause
Remedy
1
Connection failure of the panel
flat cable
Reconnect the panel flat cable.
2
Connection failure of the key
PCB flat cable
Reconnect the key PCB flat cable.
3
Touch panel ASSY failure
Replace the touch panel ASSY.
4
Key PCB failure
Replace the key PCB ASSY.
5
Panel PCB failure
Replace the panel PCB ASSY.
6
Panel ASSY failure
Replace the panel ASSY.
7
Main PCB failure
Replace the main PCB ASSY.
Step
Cause
Remedy
1
Main PCB failure
Replace the main PCB ASSY.
Step
Cause
Remedy
1
Main PCB failure
Replace the main PCB ASSY.
Содержание DCP-2537DW
Страница 50: ...2 10 Confidential MP models Fig 2 6 Feed from MP tray Eject to back side Back side Front side ...
Страница 51: ...2 11 Confidential 2 2 2 Scanner part Fig 2 7 Document feed path ...
Страница 159: ...3 2 Confidential 2 PACKING Fig 3 1 Option carton Carton Polystyrene pad ASSY Spacer carton Option carton TBOX ...
Страница 240: ...3 83 Confidential 9 25 Filter 1 Release the Hook to remove the Filter from the Air duct Fig 3 79 Hook Filter Air duct ...
Страница 300: ...5 28 Confidential Print adjustment test pattern Fig 5 11 ...
Страница 311: ...5 39 Confidential Print pattern Fig 5 16 W 100 K 1 K 100 Total Lattice K 5 ...
Страница 316: ...5 44 Confidential Test pattern Fig 5 19 ...
Страница 332: ...5 60 Confidential ...