2-117
Confidential
4.14.4Message indicating that the report is full does not disappear
<User Check>
• Output each report.
4.14.5Paper tray cannot be recognized
<User Check>
• Close the paper tray properly.
Step
Cause
Remedy
1
Main PCB failure
Replace the main PCB ASSY.
Step
Cause
Remedy
1
Connection failure of the T1
paper feed sensor harness
(non paper empty sensor
models only)
Reconnect the T1 paper feed sensor
harness.
2
Connection failure of the T1
paper empty/paper feed
sensor harness
(paper empty sensor models
only)
Reconnect the T1 paper empty/paper feed
sensor harness.
3
T1 paper feed sensor PCB
failure
(non paper empty sensor
models only)
Replace the T1 paper feed sensor PCB
ASSY.
4
T1 paper empty/paper feed
sensor PCB failure
(paper empty sensor models
only)
Replace the T1 paper empty/paper feed
sensor PCB ASSY.
5
Main PCB failure
Replace the main PCB ASSY.
Содержание DCP-2537DW
Страница 50: ...2 10 Confidential MP models Fig 2 6 Feed from MP tray Eject to back side Back side Front side ...
Страница 51: ...2 11 Confidential 2 2 2 Scanner part Fig 2 7 Document feed path ...
Страница 159: ...3 2 Confidential 2 PACKING Fig 3 1 Option carton Carton Polystyrene pad ASSY Spacer carton Option carton TBOX ...
Страница 240: ...3 83 Confidential 9 25 Filter 1 Release the Hook to remove the Filter from the Air duct Fig 3 79 Hook Filter Air duct ...
Страница 300: ...5 28 Confidential Print adjustment test pattern Fig 5 11 ...
Страница 311: ...5 39 Confidential Print pattern Fig 5 16 W 100 K 1 K 100 Total Lattice K 5 ...
Страница 316: ...5 44 Confidential Test pattern Fig 5 19 ...
Страница 332: ...5 60 Confidential ...