3-54
Confidential
(2) Remove the three Taptite cup B M3x10 screws to remove the Hinge arm L and the Hinge L
from the Document cover ASSY.
(3) Remove the three Taptite cup B M3x10 screws to remove the Hinge arm R and the Hinge R
from the Document cover ASSY.
Fig. 3-46
Taptite cup B M3x10
Taptite cup B M3x10
Hinge arm R
Hinge arm L
Document cover ASSY
Hinge L
Hinge R
Содержание DCP-2537DW
Страница 50: ...2 10 Confidential MP models Fig 2 6 Feed from MP tray Eject to back side Back side Front side ...
Страница 51: ...2 11 Confidential 2 2 2 Scanner part Fig 2 7 Document feed path ...
Страница 159: ...3 2 Confidential 2 PACKING Fig 3 1 Option carton Carton Polystyrene pad ASSY Spacer carton Option carton TBOX ...
Страница 240: ...3 83 Confidential 9 25 Filter 1 Release the Hook to remove the Filter from the Air duct Fig 3 79 Hook Filter Air duct ...
Страница 300: ...5 28 Confidential Print adjustment test pattern Fig 5 11 ...
Страница 311: ...5 39 Confidential Print pattern Fig 5 16 W 100 K 1 K 100 Total Lattice K 5 ...
Страница 316: ...5 44 Confidential Test pattern Fig 5 19 ...
Страница 332: ...5 60 Confidential ...