2-54
Confidential
Error code 6001
The front cover sensor detected that the front cover was open.
<User Check>
• Close the front cover.
Error code 6004
The eject sensor detected that the fuser cover was open.
<User Check>
• Close the fuser cover.
Step
Cause
Remedy
1
Connection failure of the front
cover sensor harness
Reconnect the front cover sensor
harness.
2
Front cover failure
Replace the front cover.
3
Front cover sensor failure
Replace the front cover sensor.
4
Main PCB failure
Replace the main PCB ASSY.
Step
Cause
Remedy
1
Eject actuator coming off or
caught in some sections of the
machine
Reattach the eject actuator.
2
Fuser cover attachment failure
Reattach the fuser cover.
3
Connection failure of the eject
sensor PCB harness
Reconnect the eject sensor PCB harness.
4
Eject sensor PCB failure
Replace the eject sensor PCB ASSY.
5
Main PCB failure
Replace the main PCB ASSY.
Содержание DCP-2537DW
Страница 50: ...2 10 Confidential MP models Fig 2 6 Feed from MP tray Eject to back side Back side Front side ...
Страница 51: ...2 11 Confidential 2 2 2 Scanner part Fig 2 7 Document feed path ...
Страница 159: ...3 2 Confidential 2 PACKING Fig 3 1 Option carton Carton Polystyrene pad ASSY Spacer carton Option carton TBOX ...
Страница 240: ...3 83 Confidential 9 25 Filter 1 Release the Hook to remove the Filter from the Air duct Fig 3 79 Hook Filter Air duct ...
Страница 300: ...5 28 Confidential Print adjustment test pattern Fig 5 11 ...
Страница 311: ...5 39 Confidential Print pattern Fig 5 16 W 100 K 1 K 100 Total Lattice K 5 ...
Страница 316: ...5 44 Confidential Test pattern Fig 5 19 ...
Страница 332: ...5 60 Confidential ...