3-91
Confidential
MP models
(6) Remove the three Taptite bind B M4x12 screws to remove the Front chute ASSY. Pull out
the MP paper empty sensor harness from the Hole of the Frame L unit.
(7) Release the LVPS harness from the securing fixtures.
(8) Remove the Regist FG spring from the Motor drive sub ASSY and the Conductive bushing 5.
(9) Use a flat-blade screwdriver or similar tool to release the Hook from the Hole, and remove
the Conductive bushing 5.
(10) Release the Hook, and remove the Feeder gear 34.
Fig. 3-90
Harness routing: Refer to
“11. Frame L unit (MP models)”
.
Taptite bind
B M4x12
Front chute ASSY
Hook
Regist FG spring
Conductive bushing 5
Conductive bushing 5
Feeder gear 34
<Front side>
Hook
Motor drive sub ASSY
Regist FG spring
LVPS harness
<Upper side of Frame L>
Hole
MP paper empty sensor harness
Hole