2-48
Confidential
Error code 0401
BD sensor failure (second time)
Error code 0405
BD sensor failure (first time)
<User Check>
• There is a possibility of condensation. Leave the front and back cover open for at least 30
minutes when the power is ON. Close those covers and turn the power switch OFF and then
back ON again.
Step
Cause
Remedy
1
Connection failure of the laser
unit flat cable
Reconnect the laser unit flat cable.
2
Laser unit failure
Replace the laser unit.
3
Main PCB failure
Replace the main PCB ASSY.