4.12 Troubleshooting for Scanning Image Defect
4.12.1Defect examples
Fig. 2-24
4.12.2Troubleshooting according to image defect
Light
<User Check>
• Check that the contrast setting is not too light.
• Clean the scanner glass or first side/second side scanner glass strip.
• Clean the document hold.
Step
Cause
Remedy
1
Incorrect white level
correction data
Execute “Acquire white level data
2
First or second side CIS unit
failure
Replace the first or second side CIS unit.
3
Main PCB failure
Replace the main PCB ASSY.