2-23
Confidential
Error
Codes
Description
Refer
to:
Error
Codes
Description
Refer
to:
9706 ---
9D04 ---
9801 ---
9D05 ---
9802 ---
A000
Image processing was not completed
correctly because the number of pixels
required for image processing is insufficient
in the scanned second side data.
9803 ---
A200
The document scanning position sensor
detected that the document length was 90
cm or more during the one-side scanning.
9804 ---
A300
The document scanning position
sensor has not detected the document
passing even after the document has
been fed for the specified time.
9901 ---
A400
The ADF cover sensor detected that
the ADF cover was open.
9902 ---
A500
When scanning the fax, white or black
correction data for the first side CIS unit
was not within the correct range (first time).
9903 ---
A600
When scanning the fax, white or black
correction data for the first side CIS unit was
not within the correct range (second time).
9A01 ---
A700
Color parameter in the ROM does not
match the first side or second side CIS.
9A02 ---
A800 ---
9A03 ---
A900
A scanning error occurred while
processing the scanned image.
9B01 ---
AA00 ---
9B02 ---
AB00 ---
9B03 ---
AC00
When scanning the fax, white or black
correction data for the second side CIS
was not within the correct range (first time).
9B04 ---
AD00
Image processing cannot be
completed correctly because the
number of pixels required for image
processing is insufficient in the
scanned first side data.
9B05 ---
AE00 ---
9B06 ---
AF00
Home position is still being detected
even after the first side CIS unit was
moved.
9C01 ---
B000
Detected that the first side CIS flat
cable or second side CIS flat cable
was not inserted correctly when
function code 55 was executed.
9C02 ---
B700 ---
9C03 ---
B800 ---
9C06 ---
B900 ---
9C07 ---
BB00
A white level not within the standard
was scanned when function code 55
was executed.
9D02 ---
BC00
When scanning the fax, white or black
correction data for the second side CIS
was not within the correct range
(second time).
9D03 ---
BD00
A black level not within the standard
was scanned when function code 55
was executed.
Содержание DCP-2537DW
Страница 50: ...2 10 Confidential MP models Fig 2 6 Feed from MP tray Eject to back side Back side Front side ...
Страница 51: ...2 11 Confidential 2 2 2 Scanner part Fig 2 7 Document feed path ...
Страница 159: ...3 2 Confidential 2 PACKING Fig 3 1 Option carton Carton Polystyrene pad ASSY Spacer carton Option carton TBOX ...
Страница 240: ...3 83 Confidential 9 25 Filter 1 Release the Hook to remove the Filter from the Air duct Fig 3 79 Hook Filter Air duct ...
Страница 300: ...5 28 Confidential Print adjustment test pattern Fig 5 11 ...
Страница 311: ...5 39 Confidential Print pattern Fig 5 16 W 100 K 1 K 100 Total Lattice K 5 ...
Страница 316: ...5 44 Confidential Test pattern Fig 5 19 ...
Страница 332: ...5 60 Confidential ...