2-67
Confidential
Error code A700
Color parameter in the ROM does not match the first side or second side CIS.
Error code A900
A scanning error occurred while processing the scanned image.
Error code AC00
When scanning the fax, white or black correction data for the second side CIS was not within
the correct range (first time).
Error code AD00
Image processing cannot be completed correctly because the number of pixels required for
image processing is insufficient in the scanned first side data.
Step
Cause
Remedy
1
Incorrect correction data for first
side or second side CIS unit
Execute “Set CIS scan area
”.
2
Damaged first side CIS flat cable
Replace the first side CIS flat cable.
3
Damaged second side CIS flat
cable
Replace the second side CIS flat cable.
4
First side CIS unit failure
Replace the first side CIS unit.
5
Second side CIS unit failure
Replace the second side CIS unit.
6
Main PCB failure
Replace the main PCB ASSY.
Step
Cause
Remedy
1
Incorrect correction data for
second side CIS unit
Execute “Acquire white level data
2
Dirt on the white tape on the
second side document hold
Clean the white tape on the second side
document hold.
3
Damaged second side CIS flat
cable
Replace the second side CIS flat cable.
4
Second side CIS unit failure
Replace the second side CIS unit.
5
White tape failure
Replace the ADF unit.
6
Main PCB failure
Replace the main PCB ASSY.
Step
Cause
Remedy
1
Incorrect correction data for first
side CIS unit
Execute “Set CIS scan area
”.
2
Connection failure of the first
side CIS flat cable
Reconnect the first side CIS flat cable.
3
First side CIS unit failure
Replace the first side CIS unit.
4
White tape failure
Replace the document scanner unit.
5
Main PCB failure
Replace the main PCB ASSY.
Содержание DCP-2537DW
Страница 50: ...2 10 Confidential MP models Fig 2 6 Feed from MP tray Eject to back side Back side Front side ...
Страница 51: ...2 11 Confidential 2 2 2 Scanner part Fig 2 7 Document feed path ...
Страница 159: ...3 2 Confidential 2 PACKING Fig 3 1 Option carton Carton Polystyrene pad ASSY Spacer carton Option carton TBOX ...
Страница 240: ...3 83 Confidential 9 25 Filter 1 Release the Hook to remove the Filter from the Air duct Fig 3 79 Hook Filter Air duct ...
Страница 300: ...5 28 Confidential Print adjustment test pattern Fig 5 11 ...
Страница 311: ...5 39 Confidential Print pattern Fig 5 16 W 100 K 1 K 100 Total Lattice K 5 ...
Страница 316: ...5 44 Confidential Test pattern Fig 5 19 ...
Страница 332: ...5 60 Confidential ...