3-19
Confidential
11
Frame L unit (MP models)
Harness colors are subject to change for some reason.
T1 clutch
HVPS flat cable
Laser unit flat cable
Front cover sensor harness (YW)
Back cover/duplex tray
sensor harness (RD, BL)
T1 clutch harness (BL)
Registration clutch harness (WH)
Polygon motor harness (WH)
LVPS harness (WH, BK)
Paper feed motor flat cable
Registration clutch
Paper feed sensor harness (WH)
MP relay PCB ASSY
Eject sensor
flat cable
Main PCB ASSY
Cartridge sensor harness (WH) *
* For models without Toner box
MP paper empty
sensor harness (RD)
MP sensor harness (BK)
MP relay flat cable