24
GB
16. Calibration is completed: the machine automatically exits the calibration program and returns to
the NORMAL mode, ready to perform the balancing.
If during machine calibration there are some anomalies, error codes will be displayed (e.g.
Err 025
). See
chapter 6.1
Error Codes
and act accordingly to eliminate the problem and to continue/repeat/cancel the
calibration in progress.
4.2.1 How to exit the CAR/SUV Wheel Type calibration
You can exit the ongoing calibration procedure at any time by pressing [F + P3]
. The
machine will return to the SERVICE mode displaying the writing SER SER. To return to the NORMALE mode,
press [F+P3]
again.
The calibration procedure in progress will be cancelled and the balancing results will use previous cali-
bration values.
4.3 Calibration according to the MOTO Wheel Type
Calibration for the MOTO Wheel Type (wheels for motorbikes) is completely separate from the machine
calibration for the CAR/SUV Wheel Type because it takes into account the fact that the machine uses a
special flange for motorcycle wheels that slightly alters the balancing of the shaft.
If MOTO Wheel Type calibration has not been carried out and you try to run a balancing launch when the
MOTO Wheel Type is selected, the machine will not run the launch and will display the error code
ERR 031
.
To calibrate motorbike wheels, proceed as follows:
1.
Switch the machine on;
2. Attach
the flange
to
the shaft for motorbike wheels as shown in Figure
F4.1.
CAL
CAL
Fig. F4.1 Application of the motorbike flange onto the shaft. Align the writing “Cal” on the flange
and on the flange for motorbikes
+
+