Analog and Frequency Inputs | 10
Bosch Motorsport
Modular Sensor Interface MSI 60
57 / 120
8.
The channel is inserted into the MSI 60 Project Tree.
a) Channel is linked to ANA05.
b) Available measurements for channel.
c) Input pin pull-up resistor is activated.
d) Calculation of physical value with characteristic curve.
Available measurements for channel
Measurement label
Function
raw_name
mV value of sensor
raw_name_fi
filtered mV value of sensor
name
physical value of sensor
name_fi
filtered physical value
10.3.2 Configuring a generic linear Sensor
Example: Acceleration sensor 5 g
– From sensor data sheet – operating characteristics:
– Sensitivity 400 mV/g, Offset 2,500 mV
– The sensor has a linear output signal with sensitivity and offset.
1.
Click on ‘Measurement Sources’ in the Toolbox.
2.
Expand the list of ‘I/O Channels’ by clicking on ‘+’ in the MSI 60 Project Tree.
3.
Drag the ‘Sensitivity/Offset’ analog signal source from the Toolbox and drop it on the
desired analog input channel in the MSI 60 Project Tree.
A ‘Sensitivity/Offset Wizard’ opens.
Содержание MSI 60
Страница 1: ...Modular Sensor Interface MSI 60 Manual 1 25 01 2019 ...
Страница 21: ...Mechanical Drawing 6 Bosch Motorsport Modular Sensor Interface MSI 60 21 120 6 Mechanical Drawing ...
Страница 23: ...Starting up 7 Bosch Motorsport Modular Sensor Interface MSI 60 23 120 1 Start the RaceCon software ...
Страница 117: ...Bosch Motorsport Modular Sensor Interface MSI 60 117 120 ...
Страница 118: ...118 120 Modular Sensor Interface MSI 60 Bosch Motorsport ...
Страница 119: ...Bosch Motorsport Modular Sensor Interface MSI 60 119 120 ...
Страница 120: ...Bosch Engineering GmbH Motorsport Robert Bosch Allee 1 74232 Abstatt Germany www bosch motorsport com ...