7 | Starting up
26 / 120
Modular Sensor Interface MSI 60
Bosch Motorsport
RaceCon detects configuration differences between the MSI 60 and the RaceCon pro-
ject and asks for permission for data download.
8.
Click ‘OK’ to proceed.
The download starts and the MSI 60 carries out a reset. After the reset RaceCon recon-
nects to the MSI 60 . Local configuration on both the PC and MSI 60 match (indicated by
green background and dot). The MSI 60 is now connected to RaceCon.
7.2 Assign the Mounting Location
Because up to eight MSI 60 can be used in one network for I/O expansion, the mounting
location is used for determination between the different MSI 60.
At delivery no mounting location is set. This is signaled by an orange ‘RUN’ LED on the
device. Therefore one must first assign a mounting location to the MSI 60 before it can be
used in the project. The mounting location is permanently saved in the MSI 60. If neces-
sary you can at any time reassign a different mounting location following the same pro-
cedure.
A mounting location must not be used several times in one network, this would disturb
the functionality of the respective MSI 60.
Содержание MSI 60
Страница 1: ...Modular Sensor Interface MSI 60 Manual 1 25 01 2019 ...
Страница 21: ...Mechanical Drawing 6 Bosch Motorsport Modular Sensor Interface MSI 60 21 120 6 Mechanical Drawing ...
Страница 23: ...Starting up 7 Bosch Motorsport Modular Sensor Interface MSI 60 23 120 1 Start the RaceCon software ...
Страница 117: ...Bosch Motorsport Modular Sensor Interface MSI 60 117 120 ...
Страница 118: ...118 120 Modular Sensor Interface MSI 60 Bosch Motorsport ...
Страница 119: ...Bosch Motorsport Modular Sensor Interface MSI 60 119 120 ...
Страница 120: ...Bosch Engineering GmbH Motorsport Robert Bosch Allee 1 74232 Abstatt Germany www bosch motorsport com ...