Program Entry Guide 

Control Panels 

 

D9412GV2/D7412GV2

 

Содержание D7412GV2

Страница 1: ...EN Program Entry Guide Control Panels D9412GV2 D7412GV2 ...

Страница 2: ...mple Shaded boxes indicate programmer prompts that are only available when Custom or View events are selected Sub Prompt A dashed border indicates a sub entry under a main programming entry Tips Notes Cautions and Warnings Throughout this document helpful tips and notes are presented concerning the entire application or programming the unit They are displayed as follows Important Notes These notes...

Страница 3: ...ptions 39 2 9 6 Arming Features 43 2 10 Keypad 45 2 10 1 Cmd Cntr Keypad Assignment 45 2 10 2 Area Text 50 2 11 User Interface 54 2 11 1 Commands 54 2 11 2 Keypad Selections 54 2 11 3 Access Control Functions 57 2 11 4 Authority Level Selections 61 2 11 5 Access Control Levels 69 2 12 Function List 70 2 13 Relay Parameters 71 2 13 1 Area Relays 72 2 13 2 Panel Wide Relays 74 3 0 RADXUSR1 RADXUSR2 ...

Страница 4: ...s 16 Table 10 User Reports 16 Table 11 Test Reports 17 Table 12 Diagnostic Reports 18 Table 13 Relay Reports 18 Table 14 Auto Function Reports 18 Table 15 RPS Reports 19 Table 16 Point Reports 19 Table 17 User Change Reports 20 Table 18 Access Reports 20 Table 19 Event Descriptions Priorities and Numbers 23 Table 20 Programming Four Digit Account Numbers 32 Table 21 Programming Ten Digit Account N...

Страница 5: ...6 Passcode protected custom functions 16 4 Number of printers 3 1 Number of points 246 75 Number of relays 128 64 Table 2 Literature Referenced Document Name Part Number 1 D1255 Installation Instructions 74 06819 000 2 D1256 D1257 Installation Instructions 74 06925 000 3 D1260 Installation Guide 48101 4 D1260 Owner s Manual 50410 5 D5200 Operations Manual 74 06176 000 6 D6500 Report Directory 74 0...

Страница 6: ...ion D9412GV2 D7412GV2 GV2MAIN V1 00 and above Covers Panel Wide Area Keypad Function List User Interface and Relay programming modules RADXUSR1 V1 06 and above Covers passcode and token programming for users 000 through 124 users 000 through 099 for the D7412GV2 RADXUSR2 V1 05 and above Covers passcode and token programming for Users 125 through 249 N A RADXPNTS V1 06 and above Covers Point Index ...

Страница 7: ...rogramming modules within the D5200 Programming Custom as Yes allows parameters for special applications to be visible in the programmer 1 4 Programming the Control Panel with the D5200 Programmer Caution Do not connect the D5200 to the PROG connector without closing the reset switch Doing so causes SDI TROUBLE and CALL FOR SERVICE to display on the keypads Door controllers also activate depending...

Страница 8: ...D9412GV2 D7412GV2 Program Entry Guide 1 0 Introduction EN 8 Bosch Security Systems 5 05 F001U003636B Notes ...

Страница 9: ...erred to in the prompts in Section 2 3 Routing on page 13 The control panel is programmed with a seven second dial tone detect period When a dial tone is detected or the waiting period ends the control panel begins to dial To extend the dial tone detect period place a D before the phone number To insert a pause during or after dialing use C in the number sequence For example if the control panel h...

Страница 10: ...sends a flag with each report telling the D6500 D6600 to convert point numbers and User ID numbers to COMEX format Refer to Table 5 and Table 6 for conversion information When this parameter is programmed Yes points and User ID numbers are converted regardless of the programming of the D6500 or D6600 Receiver for output to the computer system Refer to the D6600 Communications Receiver Gateway Comp...

Страница 11: ...e When using Independent Zone Controls IZC to send Opening Closing Reports by point do not duplicate reporting independent point numbers with User ID Reports refer to Section 3 1 Pass Code or Token Worksheet on page 77 For example If an IZC is connected to Point 8 do not use User ID 8 D6000 Opening Closing User ID numbers are identified at the receiver as ZONEs same identification as independent p...

Страница 12: ...for Area 1 or the account number associated with Area 1 Phone Supv Time must be programmed to use this feature Phone Failure Alarm Responses The Alarm Bell relay for Area 1 activates All Phone Event messages report as Area 1 and the account number for Area 1 Buzz on Fail Default No Selection Yes or No Yes Generate panel wide trouble tones and display PHONE FAIL at keypads when a Phone Fail Event o...

Страница 13: ...ogram a group first choose a route number The lower the route number the higher priority that group has for example events reported for Route 1 have a higher priority than Routes 2 3 or 4 if each group tries to send a message at the same time The priority of the route numbers becomes important when programming duplicate reports or choosing the events you want to report first regardless of the numb...

Страница 14: ...mpt refer to Route Group Attempts on page 131 If RG 1 Attempt is set to No the control panel makes up to six dialing attempts using the primary device within a route group If unsuccessful it makes up to four dialing attempts using the backup device before initiating a Comm Fail Report When only one destination is programmed the control panel makes ten attempts to contact that destination Each grou...

Страница 15: ...ch routing group and program individual events for this route group only D5200 No Continue programming without viewing individual groups The D5200 Programmer reveals the following sub prompts Leaving View Events as No allows the user to ignore a large area of programming that might not need to be changed Fire Reports Selecting Yes enables a report to be sent when the event occurs Table 8 Diagnosti...

Страница 16: ...o an alarm condition then restores before the Cross Point Time elapses R Unverified Evt encompasses both Fire and Non fire points but is not related to the A Verify Time used for smoke detectors The 9000GV2 Series control panels log a Ground Fault Event as Trouble Point 256 Restoral Reports are not sent if the control panel resets after a point is bypassed and then unbypassed This is true for both...

Страница 17: ...ng Sked Function Code 29 To generate this event one or more points must be in an off normal state at the time the Sked executes Expanded Off Normal Test Reports include the Off Normal Test Report Event as well as events for any points that are in an off normal state at the time the report is generated Non Expanded Off Normal Test Report Events are sent only when a point is in the off normal state ...

Страница 18: ...network R Network Rest2 Yes No Restoral of network R Network Cond2 Yes No Condition of network Indicates an off normal event 1 This event covers Comm Fail Route Group and Comm Fail Phone If enabled both events are sent if disabled neither event is sent 2 This event is reserved for future use Enable Rt Comm Fail and Rt Comm Restore in only one route group Enable Rt Comm Fail and Rt Comm Restore in ...

Страница 19: ...Access Event R RPS Fail Yes No Failed Access RPS Event R Remote Reset Yes No Remote Reset Event R Program OK Yes No Successful Laptop Access Event R Program Fail Yes No Failed Laptop Access Event Point Reports Selecting Yes enables a report to be sent when the event occurs Table 16 Point Reports Report Selections Report Description R Service Start Yes No Reorts Service Walk Test Start Event R Serv...

Страница 20: ...Event R Change Level Yes No Access Control Level Change Event With R Delete User Events the control panel always uses the account number from Area 1 Access Reports Selecting Yes enables a report to be sent when the event occurs Access Granted No Entry Request to Enter RTE and Request to Exit REX Events can be enabled or disabled by each D9210B Table 18 Access Reports Report Selections Report Descr...

Страница 21: ...e Group 2 sends a fire alarm report first to Route Group 1 followed by a duplicate report to Route Group 2 Section 2 4 Enhanced Routing on page 21 determines the route groups and which destinations within the route groups use network interface modules NIMs for reporting purposes A single NIM can send events to as many as four different destinations For example if you want to send events using Rout...

Страница 22: ...ger To send events to a numeric pager a phone number must also be programmed in the route group s primary destination If programming the control panel to dial a numeric pager choose its route group carefully Place events being sent to a central station in a route group class with a lower number than the numbers of the events in the route group for the numeric pager Numeric Pager Capability The D94...

Страница 23: ...o show in the pager message To limit the number of fields shown in the pager message enter the appropriate number of characters in the phone number as shown below Zero characters in phone number Shows all four fields One character in phone number Shows first field only Two characters in phone number Shows first two fields Three characters in phone number Shows first three fields Four or more chara...

Страница 24: ...ery Missing 004 074 Battery Low 004 075 Battery Restoral 008 076 Route Comm Fail 004 066 Route Comm Restore 008 067 Checksum Fail n a n a Sensor Reset 007 031 Relay Set 007 032 Relay Reset 007 033 Sked Executed 007 057 Sked Changed 007 058 Fail to Execute 008 151 Event Log Threshold 008 052 Event Log Overflow 008 053 SDI Device number is not reported when using pager format Table 19 Event Descript...

Страница 25: ...il Time interval is in seconds and an AC Fail Event is sent after the loss of AC for this amount of time An additional AC Fail Event is sent after 6 hours if the AC Fail condition is still present 9 such as 9 19 29 39 and so on The AC Fail Time interval is in minutes and an AC Fail Event is sent after the loss of AC for this amount of time An additional AC Fail Event is sent after 12 hours if the ...

Страница 26: ...mmercial fire systems Be sure to program AC Fail Res Rpt as No if AC Tag Along is programmed Yes AC Battery Buzz Default No Selection Yes or No Yes Initiates panel wide trouble tone at all keypads No Does not initiate panel wide trouble tone at keypads Initiates a panel wide trouble tone at keypads when AC fails or battery is low or missing This program item does not prevent the SERVC AC FAIL or S...

Страница 27: ... panel does not generate Trouble SDI Reports for the printer if the D9131A becomes disconnected P Scope Default No Printer Selection No Printer Area Account Panel Wide Custom Panel Wide Printer prints all designated events that occur panel wide A panel wide printer can cross account boundaries Account Printer prints all designated events that occur within any area with the same account number in w...

Страница 28: ... phone connection Two other methods of remote programming are available external modem and LAN or WAN connection using RPS Refer to Section 6 4 SDI RPS Parameters on page 121 for more information on these types of remote programming 2 7 1 Uploading and Downloading Reports If the control panel is programmed to send reports in modem format when RPS contacts the control panel and the passcode is inco...

Страница 29: ...bandoning the effort Remote Program Dialing Exception When an RPS phone number is programmed the user can call RPS by entering COMMAND 4 3 and pressing the NEXT key until CALLRPS is displayed Press ENTER Only one attempt is made to contact RPS RPS Passcode Default 999999 Selection 0 to 9 A to F six characters required Enter six characters Do not use a space in the passcode The control panel verifi...

Страница 30: ...line with an answering machine to communicate with RPS at the central station even though the answering machine answers the phone You must program Answer Armed or Answer Disarmed The control panel must be in the correct armed state Program this item No if it causes false seizures of the phone line or if you do not use RPS This indicates that a device using the same frequency tone is also using the...

Страница 31: ... using this method Refer to Section 6 4 SDI RPS Parameters on page 121 for other corrections methods Refer to Phone 1 in Section 2 1 Phone 2 8 Miscellaneous Duress Type Default 1 Selection 1 or 2 1 Increase the last digit by 1 to generate an alarm For example if the passcode is 6123 6124 activates a duress alarm If the last digit of the passcode is 0 a duress alarm occurs when the user enters 1 as...

Страница 32: ...r Modem four digit account numbers 0000 to 9999 BBBB to FFFF For Modem ten digit account numbers 0000000000 to 9999999999 BBBBBBBBBB to FFFFFFFFFF Determines the account number for this area An account number must be assigned to each active area Account numbers are used to group areas together Each area can have a different account number or several areas can share the same account number The cont...

Страница 33: ... 5 5 The D5200 account number entry shown in Table 21 appears in RPS as shown in Figure 2 Figure 2 Account Number Entry 2 2 3 3 4 4 5 5 1 1 2 3 4 5 6 7 1 1 RPS account number entry 2 Corresponding D5200 account number digits 3 Digits 1 and 2 4 Digits 3 and 4 5 Digits 5 and 6 6 Digits 7 and 8 7 Digits 9 and 10 Although the D5200 allows the character A to be entered into the account do not use this ...

Страница 34: ...ification time allowed Points are programmed individually to activate the verification feature Refer to Section 4 1 Point Index on page 81 Any resettable Fire point can activate alarm verification for the area to which it is assigned Use separate area alarm verification relays To enable alarm verification on a point program Point Index Fire Point Alarm Verify and Resettable as Yes When an Alarm Ve...

Страница 35: ... Verification point activates Example Total Cycle time 80 seconds 20 Seconds 60 Seconds A Duress Enable Default No Selection Yes or No Yes Enable Duress alarm for this area No Disable Duress alarm for this area Refer to Duress Type in Section 2 8 Miscellaneous on page 31 for an explanation of duress The passcode you normally use for duress is not valid in an area with A Duress Enable set to No Set...

Страница 36: ...nel Wide or Account Wide When arming a master area from a keypad with CC Scope set to Panel Wide or Account Wide all associate areas enters exit delay as soon as the master area is armed If there is a shared area within the same account it begins its exit delay after all associate areas are armed Using the arming sked S Function 1 requires that you first use an arming sked to arm the associate are...

Страница 37: ...es from any keypad To silence sounders the user needs an authority level assigned to the shared area If the user also has the authority to arm or disarm the area then ALREADY ARMED or ALREADY DISARMED momentarily appears Access Control Readers Assigned to the Shared Area The shared area momentarily disarms then begins the exit delay sequence allowing a user to walk to an associate area and disarm ...

Страница 38: ...5 seconds Off 0 5 seconds On 1 5 seconds Off pattern repeats This sequence repeats for a minimum of 3 minutes and with a 10 tolerance Select the bell pattern this area uses to signal an alarm on a Fire point Press the Space bar to scroll through the selections Press Enter when the correct selection appears in the display When an alarm occurs on two Fire points sharing the same relay the bell patte...

Страница 39: ... receives an acknowledgment from the central station receiver For proper operation of the Bell Test after closing confirmation the following rules apply The control panel must send Opening and Closing Reports to the central station Do not use restricted openings and closings or Opening and Closing Windows Area Armed Confirmation In areas that do not report opening and closing activity the alarm be...

Страница 40: ... Opening Reports When the first area in the account is disarmed it generates an Account Opening Report along with an Area Opening Report When the remaining areas in the account are disarmed each area generates an Area Opening Report Area Only Opening Closing Supervision Features Use these features to supervise opening and closing activity by area Auto Close Fail To Open and Fail To Close all work ...

Страница 41: ...opening or closing occurs outside of the appropriate window it reports but does not have an early or late modifier If you want to monitor all opening and closing activity and use features provided by Opening and Closing Windows program this item as No and program the appropriate O C Windows Determines if opening and closing activity is reported when it occurs inside an Opening or Closing Window as...

Страница 42: ...s the area sends only Restricted Opening and Closing Reports In this case Restricted Reports are sent without User ID Opening Closing Window does not affect this report Windows do not prevent sending Restricted Opening and Closing Reports from being sent Early or late designations are not added to Opening or Closing Reports when they are sent according to the rules for Restricted Opening or Closin...

Страница 43: ... the next day when the control panel clock turns to midnight The control panel must cross the midnight boundary before any changes in that default setting occur To extend across midnight you must use two windows To suppress reports before midnight use one window for example 20 00 start to 23 59 stop To suppress reports immediately after midnight use another window for example 00 01 start to 02 00 ...

Страница 44: ... second code When the first digit of the second code is pressed the following message appears As each digit is pressed an additional asterisk appears A Early Ambush Default No Selection Yes or No Yes Two valid passcodes are required to disarm the area within the time period specified in Early Ambush Timer The second valid disarm passcode must be entered within a time limit Refer to Early Ambush Ti...

Страница 45: ... behavior of the two pass codes 2 10 Keypad Command Center This programming module contains three programming categories Cmd Cntr Assignment Area Text and Custom Function 2 10 1 Keypad Command Center Assignment This programming category assigns a keypad to an area and determines if the keypad is supervised The keypads are connected to the control panel using a two wire serial data interface SDI bu...

Страница 46: ...ming functions for all areas in the control panel A panel wide keypad can cross account boundaries This is normally used with a master area Account An Account keypad can view information and perform Arming and Disarming functions for all areas with the same A Acct Number in Area Parameters This is normally used for an associate area Area An area keypad is restricted to viewing information and Armi...

Страница 47: ...ess control strike on a door does not shunt a point When programmed to activate a relay the ENTER key cannot be used for any other function Relays used for this function must not be shared with any other point sensor reset control panel or bell functions Sharing can cause errors in relay operation CC Entr Cycl Dr Default No Selection Yes or No Yes The ENTER key is used to cycle the door programmed...

Страница 48: ...re available to a valid user at any keypad with access to the area where the door is assigned During the Add User Mode tokens or cards door control requests and RTE REX do not function Put the Door Mode into an unlocked state before adding users if there is heavy activity for this door CC Trouble Tone Default Yes Selection Yes or No Yes Panel wide trouble tones sound and visual displays show at th...

Страница 49: ...keypad sounds a tone and displays the PLEASE CLOSE NOW warning on the keypad when a Closing Window activates indicating the area automatically arms soon CC Close Door Default No Selection Yes or No Yes This keypad sounds a tone and displays CLOSE DOOR No This keypad does not sound the tone or activate the display Determines whether this keypad sounds an audible tone and displays the CLOSE DOOR war...

Страница 50: ...rm Level The user does not need disarming and arming authority for the keypad You can use this prompt for a group of account wide keypads that only arm the area to which they are assigned even if the user has a pass code with arming authority rights in all areas CC Menu Key Lock Default No Selection Yes or No Yes If set to Yes the user is prompted to enter a pass code after pressing the Menu key o...

Страница 51: ...ber The ACCT IS ON text also appears if only one area in the system is used Refer to the prompts CC Area Assign and Area Acct Is On in Section 2 10 1 Keypad Command Center Assignment on page 45 When all areas in the account are master armed the Area Is On text is replaced by the ACCT IS ON text if the area is armed before all other areas with the same account number Blank Entry A blank entry disab...

Страница 52: ...he Custom Function number you want to program You can program up to sixteen Custom Functions which are numbered 128 to 143 CF Text Default Refer to the program record sheet Selection Sixteen alphanumeric characters See Section 2 10 2 Area Text on page 50 for valid character entries Determines the menu text displayed at the keypad for the custom function item Use this text to represent the function...

Страница 53: ...cted ENTER PASSCODE appears at the keypad The user must enter a valid pass code must be entered before proceeding with the rest of the Custom Function If a pass code is not entered within 10 seconds the Custom Function times out and the display returns to idle text Skeds cannot execute Custom Functions that are pass code protected The D720 LED keypad does not support Custom Functions that are pass...

Страница 54: ... for that area When the pass code is entered at the keypad the control panel checks the authority level The control panel executes the function only in areas where the pass code has the authority to use the function 2 11 1 Commands Similar to command initiation used in other Bosch Security Systems products the Commands method provides continuity in the arming commands across product lines and make...

Страница 55: ...ter Arm Delay COMMAND 1 Use this arming function to master arm disarmed areas If enabled the following arming choices are available to the user with this authority Mstr Arm Inst Default Blank Selection Blank E or P Function No Function Name Alternate Keystroke 3 Master Arm Instant COMMAND 1 1 Use this arming function to master arm instant areas that are disarmed If enabled the following arming cho...

Страница 56: ...g View Area Stat Default P Selection Blank E or P Function No Function Name Alternate Keystroke 8 View Area Status Menu function only Use this function to view the armed status of all areas within the scope of the keypad assigned to this area The armed states include A AREA IS OFF disarmed A AREA IS ON master delay armed ALL ON INSTANT master instant armed and AREA PERIM ON perimeter instant armed...

Страница 57: ...oor Control COMMAND 4 6 This top level display must be enabled for the user to access the cycle door unlock door and secure door functions refer to Section 2 11 4 Authority Level Selections on page 61 Use this item when programming door control in your function menu Access Ctl Level Default P Selection Blank E or P Function No Function Name Alternate Keystroke 37 Access Control Levels Menu functio...

Страница 58: ... names This function deletes the pass code master user and all sub users associated with the user number Extend Close Default P Selection Blank E or P Function No Function Name Alternate Keystroke 20 Extend Close COMMAND 5 1 Use this function to change the expected closing time for the area The window cannot be adjusted until the Close Early Begin time passes and the Closing Window is active View ...

Страница 59: ...e scope of the keypad can be unbypassed where the function is entered refer to Section 2 10 1 Keypad Command Center Assignment on page 45 The control panel responds to alarms and troubles and displays point faults when a point is unbypassed Reset Sensors Default E Selection Blank E or P Function No Function Name Alternate Keystroke 27 Reset Sensors COMMAND 4 7 Use this function to activate the Res...

Страница 60: ...ontrol panel regardless of the P Type The Service Walk Test is available on the D9412GV2 using the Service Menu 9 9 ENT The D7412GV2 does not include the Service Walk Test in the Service Menu In the D7412GV2 the Service Walk Test function must be enabled in the Function List to access the Service Walk Test Default Text Default P Selection Blank E or P Function No Function Name Alternate Keystroke ...

Страница 61: ...thority level you are programming Press the SPACE bar to scroll through the selections Press ENTER when the correct selection appears in the display Table 26 Authority Level Selections Authority Level Description Blank Disabled This function is not authorized for the user who is assigned this authority level E Enabled This function is authorized for the user who is assigned this authority level Au...

Страница 62: ...ion Blank or E Function No Function Name Alternate Keystroke 4 Perimeter Instant Arm COMMAND 2 Instant arm all Perimeter points including Delayed points only in the area where the keypad is assigned L Perim Delay Default Refer to the program record sheet Selection Blank or E Function No Function Name Alternate Keystroke 5 Perimeter Delay Arm COMMAND 3 Delay arm all Perimeter Delay point responses ...

Страница 63: ... TESTED and an All Points Tested Event is sent to the central station receiver if programmed when the last point is tested If enabled in Routing Walk Start and Walk End Reports are sent to the central station receiver at the beginning and end of the test To Walk Test a Door point connected to a D9210B Access Interface Module open the door without activating the door sequence or allowing it to time...

Страница 64: ...Cycle Door is disabled all three sub functions do not operate L Cycle Door Default Refer to the program record sheet Selection Blank or E Function No Function Name Alternate Keystroke None Cycle Door Menu function only Cycle Door Menu Function only To cycle the doors press number 1 through 8 on the keypad corresponding to the door number For example pressing 2 and ENTER cycles door number 2 which ...

Страница 65: ... Blank or E Function No Function Name Alternate Keystroke 37 Access Control Levels Menu function only Changing the Access Control Level in any area affects all users and all doors associated with that level for all areas General Functions L Chg Display Default Refer to the program record sheet Selection Blank or E Function No Function Name Alternate Keystroke 15 Change Display COMMAND 4 9 Change t...

Страница 66: ...n Blank or E Function No Function Name Alternate Keystroke 22 Print Event Log Menu function only Print all panel wide events from the log to the printer in the area where the user is executing this function This item can also be accessed using the Service Menu 9 9 ENT L User Cmd 7 Default Refer to the program record sheet Selection Blank or E Function No Function Name Alternate Keystroke 23 User C...

Страница 67: ... 33 Service Walk Test Menu function only Start a Service Walk Test for all 24 hour Interior or Perimeter Controlled points in the control panel Points are not included in this test if Points are in an area that is already in a Walk Test Mode Points are assigned to an area that is not enabled A Area On Points are in an area that is Master or Perimeter armed A Service Walk Test is initiated and one ...

Страница 68: ...ing this walk test The keypad shows point text when invisible points are tested The test ends when all points are tested or if the test times out after ten minutes of no activity Local event printing occurs without alarm annunciation or reports sent to the central station receiver The D1255 Keypad shows a sequential count and text related to the point after each point is actrivated and restored Th...

Страница 69: ...his area Security Level TOKEN FUNCTION When the user presents a token or card at the reader access is granted only when the user has the authority to enter the area under certain armed conditions L Disarm Level Default Refer to the program record sheet Selection I D or Blank I Users change the Master Armed state and Perimeter Armed state to Perimeter Instant The armed state does not change in othe...

Страница 70: ...menu items The D1255 displays one menu item at a time The D1260 displays up to two menu items at a time Each keypad address has one Function List The function name shown in the Functions column in the program record sheet appears in the keypad display in capital letters For example WATCH MODE appears when you select 6 Watch Mode Menu Item Default Refer to the program record sheet Selection 1 to 32...

Страница 71: ...e Relay and Individual Point Fault Relays Relay Follows Point Relays can also be used to activate when a point programmed for P RlyResp Type refer to Section 4 1 Point Index on page 81 is off normal or in an alarm condition Relay Reports When relay activity is reported to the receiver refer to Section 2 3 Routing on page 13 on board relays are reported as follows A 253 B 254 C 255 The others repor...

Страница 72: ...he bell to ring upon alarm Although Relay C is a valid entry for A Fire Bell do not program Relay C for this entry Use Relay A for the A Fire Bell A Reset Sensors Default C Selection Blank 1 to 128 1 to 64 for D7412GV2 A B or C Unlike the default relay for Alarm Bell and Fire Bell this voltage output relay Relay C de activates for 5 seconds when the Reset Sensors function is activated from the key...

Страница 73: ...8 causes the A Area Armed relay to activate at the beginning of the exit delay time A Area Fault Default Blank Selection Blank 1 to 128 1 to 64 for D7412GV2 A B or C Activates whenever a controlled P Type 1 2 3 only Perimeter or Interior point is faulted The relay remains active until all Perimeter and Interior points in the area are normal Keyswitch area armed status with LEDs Use a D8129 Module ...

Страница 74: ... To change the Fail to Close Relay into a Perimeter Armed Relay function set A7 Silent to 63 Set A Fail to Close Relay to the area to be Perimeter Armed Refer to Programming Tip 2 for additional information Programming a value other than 0 61 or 62 enables the Fire Trouble Resound feature at 12 00 AM 2 13 2 Panel Wide Relays The following eleven relay options activate when they occur anywhere in t...

Страница 75: ...he number of the relay that activates when a Non fire point enters into alarm This relay provides a steady output until the alarm is acknowledged by a valid pass code then cleared from alarm memory with an acknowledgment at the keypad This relay does not activate for silent and invisible alarms Summary Fire Tbl Default Blank Selection Blank 1 to 128 1 to 64 for D7412GV2 A B or C Activates when any...

Страница 76: ...D9412GV2 D7412GV2 Program Entry Guide 2 0 GV2MAIN EN 76 Bosch Security Systems 5 05 F001U003636B Notes ...

Страница 77: ...dows If the user is outside a window COMMAND DISABLED appears on the keypad after the user enters the pass code and presses ENTER This window does not affect tokens and cards It only affects the pass code of the master user When using the Add Change User function at the keypad the authority levels and the changes made affect the master user s pass code and the entire group s token or cards When us...

Страница 78: ... Table 28 Users 100 through 249 do not report in BFSK format Table 28 BSFK User Code Report User Code 000 to 009 User Code 010 to 019 User Code 020 to 029 User Code 030 to 039 User Code 040 to 049 User Code 050 to 059 User Code 060 to 069 User Code 070 to 079 User Code 080 to 089 User Code 090 to 099 BFSK Report 0 BFSK Report 1 BFSK Report 2 BFSK Report 3 BFSK Report 4 BFSK Report 5 BFSK Report 6 ...

Страница 79: ... users for that group can use their pass codes only between that time Between 4 00 PM that day and 8 00 AM the next day the users cannot use their pass codes To enable this user s pass code at all times leave U User Group blank User Group Window times cannot be changed from the keypad When a window is assigned to a user group the users in that group rely on the window to be active within the start...

Страница 80: ...roperly Use 319EB0 as the hexadecimal number On your calculator press HEX Enter all the hexadecimal characters into the calculator Press DEC and your hexadecimal characters convert to the following eight digits 03251888 The site number is 032 Enter it in U Mstr Site Your card data is 51888 Enter it into U Mstr Crd Data A hexadecimal number can contain all numerals If the code does not work try con...

Страница 81: ... area contains all 24 hour points the area is never armed or disarmed A Deferred Bypass Report is not sent 24 hour protection for fire doors roof hatches and so on Instead of programming this type of protection as a 24 hour point consider using a Perimeter point type with a Point Response of 9 to E 24 hour points do not show faults when an arming function is entered but Perimeter points do When pr...

Страница 82: ...e Interior point s entry delay time is less than the remaining time it shortens the entry delay time Delayed points can also activate an entry tone at the keypad refer to the P Ent Tone Off prompt in Section 4 2 Point Responses on page 85 In some cases you might need to create an Interior point that causes an instant alarm if the entry delay is not started first Use Interior Follower to create thi...

Страница 83: ...rogrammed 1 Do not connect initiating devices to a Keyswitch point N S N When this point momentarily changes from normal to shorted to normal it toggles the armed state of the area Open An open is a trouble while the point is disarmed An open is an alarm while the point is armed When this point changes from open to normal it restores 5 Trouble and Restoral Reports are not sent if Local Disarmed is...

Страница 84: ...int must be armed before an area can be armed Program Point Response as 2 Open the W1 jumper on the D279 to send area Opening and Closing Reports as programmed in Area Parameters and to provide bell control If the D279 s W1 jumper is closed no Area Open or Area Close Report is sent and alarm bells can only be silenced from a keypad no matter how the control panel is programmed Normal When this poi...

Страница 85: ...int Reporting When a group of events occurs the control panel routes and prints out Fire Reports first Visual Annunciation FIRE TROUBLES continues to scroll until the trouble clears When acknowledged a FIRE TROUBLE scroll notifies the end user that a Fire point or group of Fire points is still in trouble Panel Wide Relays Summary Fire and Summary Fire Tbl activate if a relay is assigned when any F...

Страница 86: ...our point with supervisory response when open and a trouble response when shorted When programming the point response for Inovonics Wireless Transmitters regardless of how the transmitter is programmed the D8125INV Wireless Interface always sends the off normal state to the control panel as a short and a tamper condition as an open As a result typical point responses for the Inovonics transmitters...

Страница 87: ... disables the entry delay warning tone for this point Do not set points to No if they are actually used to notify the user to disarm the system The possibility of false alarms increases if the entry delay warning is not used Entry Tone can also be turned off when programming your CC Entry Tone in Section 2 10 Keypad Command Center on page 45 that allows you to manage the tone by keypad You might w...

Страница 88: ... P Silent set to Yes is faulted while armed When a point programmed for P Silent Bell is faulted the timer for the A Burg Time starts even though the bell is not yet ringing As much as three minutes can elapse before the second attempt fails Ensure that A Burg Time is programmed to provide the amount of bell time you need minus the additional three minutes that might elapse before the bell actuall...

Страница 89: ...al before the user can silence the buzz 3 The point buzzes at the keypad for any fault condition when the area is disarmed The user cannot silence this buzz but it silences automatically when the point is restored If the fault condition results in a trouble response the keypad continues to buzz even after the user acknowledges the condition if the fault is still present The point buzzes at the key...

Страница 90: ...e P Disp as Dvc Default No Selection Yes or No Yes Display CHECK DEVICE when this point is off normal No Do not display CHECK DEVICE when this point is off normal Use P Disp as Dvc to cause the keypad to display CHECK DEVICE when a point is off normal or is acknowledged after going into alarm Use this function for devices with a dry contact output that faults a point when the device is in a troubl...

Страница 91: ...from this point No Disable Restoral Reports from this point Transmission of Restoral Reports continues if the alarm trouble or bypass by Sked RPS or Swinger bypass condition occurred when the area disarmed and the point restored Use this option to disable any Restoral Reports from this point after it returns to normal from an alarm or trouble condition P FA Retrnable Default No Selection Yes or No...

Страница 92: ...the P Swinger Byps option is set to Yes a point is automatically bypassed after the fourth alarm or trouble report is sent A swinger Bypass report is sent at the same time Programming Bypassable as Yes for Cross points can cause missed Cross Point alarms For example if Points 1 and 2 were programmed as Cross points and Point 1 was Bypassed or Force Armed Point 2 cannot generate an Alarm Cross Poin...

Страница 93: ...with an Instant point response Also Controlled points Point Types 1 2 and 3 do not follow the Cross point operation described as follows during entry or exit delay The Cross point option is designed to reduce false alarms To achieve this program two or more points within a Cross Point Group A Cross Point Group generates a Cross Point Alarm event when all points in the group are faulted within the ...

Страница 94: ...power to reset a latched alarm condition The Resettable point option is typically used with smoke detectors and glass break detectors When initiated either through a Fire Walk Test or the keypad s Reset Sensor function or when the remote programming software RPS interrupts power to the device for 5 seconds a Sensor Reset report is sent to the central station receiver When a sensor reset occurs the...

Страница 95: ...issing alarm response while disarmed POPIT modules monitor their sensor loops for three conditions loop normal loop open and loop shorted They send reports on these three conditions to the control panel The control panel uses point programming to interpret the sensor loop information sent by the POPITs and to make the appropriate system response P Area Assign Default 1 Selection 1 to 8 The areas a...

Страница 96: ...prompt is enabled for the corresponding points Refer to Table 30 Two relays can activate when this point enters into alarm if the P Rly Resp Type for this point is programmed Use these codes to activate relays on the D8129 OctoRelay or C8137 Transmitter Interface You can assign the same code to several points providing a summary zone alarm output When the point enters into alarm the relay activate...

Страница 97: ...up to sixteen characters of text to describe the point This point text appears at keypads if the point is programmed as visible and sent to the D6500 or D6600 when transmitting in Modem IIIa2 format if it is a reporting point CMD9 Point Index Default 31 Selection Blank 00 to 31 This entry selects one of the 31 P Index codes that define how the control panel reacts when a COMMAND 9 is initiated The...

Страница 98: ...D9412GV2 D7412GV2 Program Entry Guide 4 0 RADXPNTS EN 98 Bosch Security Systems 5 05 F001U003636B Notes ...

Страница 99: ...t A column labeled Sked is found in the program record sheet provided with the control panel The numbers in that column appear in D6500 and D6600 reports and local printer reports when the window Begin Time executes Window selections 1 through 8 correspond with odd numbered Skeds 41 through 55 for Open Window and correspond with even numbered Skeds 42 through 56 for Close Window For example when t...

Страница 100: ... any time an Opening Event is sent without an Early to Open or Late to Open modifier Disarming the area between the Open Window Start and open Window Stop times creates a local event in the control panel event log but does not send the Opening Report to the central station Disarming the area between the Open Window Stop time and before the next window s Open Early Begin time or midnight whichever ...

Страница 101: ... Parameters Opening Reports generated between the Open Window Start time and Open Window Stop time can be suppressed by programming A Disable O C in Window as Yes Refer to the W Open Early Begin prompt on page 100 for additional explanations of report features Do not use a time of 23 59 as a window stop time unless another window begins on the next day at 00 00 Fail to Open Reports are not sent fo...

Страница 102: ...rea before the Closing Window Start time If Opening and Closing Reports are enabled arming the area between midnight and the Close Early Begin time generates a Closing Report Additionally If A Disable O C in Window is set to Yes and the area is armed between the Close Early Begin time and the Close Window Start time the Closing Event is sent with an Early to Close modifier If the Close Early Begin...

Страница 103: ...the end of the minute 00 00 is midnight 23 59 is 11 59 PM Make entries using a 24 hour clock for example 7 00 AM is entered as 07 00 2 45 PM is entered as 14 45 1 This program item is one of three required to create a Closing Window To program a Closing Window Close Early Begin and Close Window Start must also be programmed If the area is not armed by the time the Close Window Stop time expires th...

Страница 104: ...te is designated as a Holiday by the Holiday Index es selected Holiday Indexes for O C Windows You can enable up to four Holiday Indexes for use with Opening Closing Windows Enable at least one Holiday Index if W Xept Holiday is programmed as Yes for this window or if you want this window to activate only on specific dates Holidays are programmed in Section 5 3 Holiday Indexes on page 117 W Holida...

Страница 105: ... _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Yes No 1 2 3 4 1 2 3 4 5 6 7 8 Table 37 Opening and Closing Windows Day of Week The column below briefly describes how to activate an Opening Closing Window Use the guidelines shown in the other columns to choose the appropriate entries eXcept On Holiday Holiday Index Areas Program at least one day Yes Day s of the week No None Program at least one area Y...

Страница 106: ... 1 2 User Group Windows In this section you can create up to eight User Group periods where the pass codes for the group chosen is enabled One user group can have multiple windows assigned to it over a 24 hour period Refer to the U User Group prompt in Section 3 1 Pass Code or Token Worksheet to assign individuals to a group When you assign a U User Group to one of the eight windows all pass codes...

Страница 107: ...he window starts Beginning at this time users assigned to this window s group can use their pass codes The window goes into effect at the beginning of the minute Make entries using a 24 hour clock for example 7 00 AM is entered as 07 00 2 45 PM is entered as 14 45 Reboot the control panel to activate today s window The window needs to activate on the same day you program it UW Group Disable Defaul...

Страница 108: ... 40 Skeds can be programmed A sked can be edited from the keypad if S Time Edit is Yes The date and time can be changed using the Change Sked function Each sked number can be programmed with one of 24 functions for the S Function Code In addition to the function a choice must be made as to what is affected by the function For example when choosing Function 2 Disarm Sked the disarming is the functi...

Страница 109: ...rm Area Do not arm Area S Area 1 through 8 2 Disarm Area This function emulates the Disarm_ _ _ keypad function Entries in the S Area prompts define the area s this sked disarms The sked can disarm multiple areas Default No Selection Yes or No Enable the sked to disarm the areas indicated with Yes Yes No Disarm Area Do not disarm Area S Point Number 3 Bypass a Point This function emulates the Bypa...

Страница 110: ... on The entry in the S Relay Number prompt defines the specific relay this sked activates The sked can activate one relay Default Blank Selections Blank 1 to 128 for D9412GV2 1 to 64 for D7412GV2 Enter the number of the relay the sked activates 1 to 128 Relay to activate S Relay Number Blank No relay is turned off 7 Relay Off This function emulates the Chg Relay keypad function to turn relays off ...

Страница 111: ... listed in Diagnostic Reports and Test Reports refer to Section 2 3 8 Dialing Attempts on page 14 The Test Report can be deferred if any other report was sent since the last Test Report To defer the Test Report program S Defer Test The Test Report can be sent every hour beginning at the time scheduled in S Time To send a Test Report every hour program S Hourly Rpt Default No Selection Yes or No Se...

Страница 112: ...ns occur at the same time at the same address Functions can clash and the effect on the control panel is unpredictable Ensure that the Custom Function being executed or any of the commands nested inside the Custom Function are not pass code protected Do not program multiple skeds to execute at the same keypad during the same time Do not program skeds to execute at times when a user is likely to be...

Страница 113: ...not sound at this keypad S Access Ctl Level Default No Yes Enable Access Control Level 16 Access Control Level On This function emulates the ACCESS CMD LEVEL command that determines whether a user s token or card level is ENABLED allowing access granted rights This affects all doors that this user is assigned to with this specific authority level Selection Yes or No Activate a sked which enables t...

Страница 114: ...or 1 through 8 Default No Yes Enable the sending of Access Granted Events for Door 21 Access Authority Events On The control panel can log Access Granted Events when a valid token RTE REX or Unlock Door event is detected for a specific door These events can be directed to print at a local printer or send a report remotely through phone routing This sked enables Access Granted Events to be reported...

Страница 115: ...for Door Selection Yes or No This parameter disables the sending of No Entry Events for Door No Do not enable the reporting of No Entry Events for Door 28 Expanded Off Normal Test Report To generate this event one or more points must be in an off normal state at the time the sked executes In addition any system trouble that is active also generates an Expanded Off Normal Test Report Expanded Off N...

Страница 116: ...ds function To program a date 1 Press the two digits representing the hour 2 The cursor advances past the colon in the display 3 Press the two digits representing the minutes 4 Press ENTER S Sunday Default No Selection Yes or No Yes Activate this sked on Sundays No Do not activate this sked on Sundays This prompt and the next six prompts select the days of the week when the sked is active Exceptio...

Страница 117: ...d Change Delete section to program the Holiday Indexes The View Holidays section is a view only section provided for your convenience Use View Holidays to review the dates programmed in the Holiday Indexes 5 3 1 Add Change Delete Program the dates for each of the Holiday Indexes You can program up to four Holiday Indexes in the control panel Within each index you can select up to 365 dates to be d...

Страница 118: ...e View Holidays section is a view only section provided for your convenience Use View Holidays to review the dates you programmed into each of the Holiday Indexes You can view the first 100 dates programmed in each of the indexes Index 1 Days Default Blank Selection Enter group or press key Press ENTER GROUP to view the dates programmed in Holiday Index 1 Press key to advance to the next Holiday I...

Страница 119: ...for these options is GV2AUX version 1 0 and above It is available on the Handler Update System at Bosch Security Systems 6 3 SDI Automation SDI automation defines the characteristics of a serial interface module SIM when used with home or business automation software The SIM is a two way SDI to an RS 232 interface module that allows the control panels to send and receive information to and from an...

Страница 120: ...ptions DTR Control Default On Selection On AutoD Off On Sets DTR to on hardware control AutoD Sets this to Auto DTR Off Sets DTR off hardware control This item determines how the Data Terminal Ready DTR Control parameters are defined for the D9133 Pressing the SPACE bar on the D5200 toggles through the available options Status Rate Default 0 Selection 0 to 255 0 Status information is sent only whe...

Страница 121: ...ate with RPS by a network path Figure 6 on page 22 shows the structure of COMMAND 43 Enable SDI RPS Default Yes Selection Yes or No Yes Enable RPS sessions over the SDI bus No Do not enable RPS sessions over the SDI bus Enable SDI RPS determines if the control panel allows RPS communications over the SDI bus This item must be set to Yes if you plan to use the external modem configuration a private...

Страница 122: ...mpts determine the IP address for RPS An IP address has four fields Each field has a range of 0 to 255 For example an IP address is expressed as 110 227 64 190 Refer to Figure 7 The D5200 programmer divides the IP Address into four programmable fields Contact your network administrator to determine the IP address to which the RPS computer is connected Figure 7 RPS IP Address Prompts Set RPS IP Add...

Страница 123: ...at full line seizure is maintained Also ensure that the following items are programmed in Section 2 7 RPS Parameters on page 28 Answer Armed Blank or 0 Answer Disarmed Blank or 0 RPS Line Monitor No RPS Call Back No RPS Phone number Blank When using an external modem initialize it using the following HyperTerminal procedure on your computer The HyperTerminal procedures can vary depending upon the ...

Страница 124: ... 22 Point 7 Point 8 LEDs Off When Normal Charging Status Low Battery 12 1 VDC YEL RED 10 2 VDC Battery Load Shed This equipment should be installed in accordance with the NFPA 70 National Electrical Code and NFPA 72 National Fire Alarm Code for Local Central Station Remote Station Proprietary and Household Fire Warning Systems and under the limits of the Local Authority Having Jurisdiction Nationa...

Страница 125: ...N 16 GV2AUX SDIRPS ENHANCED CONF 9133 Supervision No 17 GV2MAIN PANEL WIDE PARAMETER Enhanced Routing RG1 Primary SDI No 18 GV2MAIN PANEL WIDE PARAMETER Enhanced Routing RG1 Backup SDI No 19 GV2MAIN PANEL WIDE PARAMETER Enhanced Routing RG2 Primary SDI No 20 GV2MAIN PANEL WIDE PARAMETER Enhanced Routing RG2 Backup SDI No 21 GV2MAIN PANEL WIDE PARAMETER Enhanced Routing RG3 Primary SDI No 22 GV2MAI...

Страница 126: ...ically answers a call if all areas are Master Armed Answer Disarmed Default 7 Selection 0 to 15 0 No answer when any area is Perimeter Armed or Disarmed 0 to 15 The control panel answers the phone after the specified number of rings when any area is Perimeter Armed or Disarmed Determines the number of rings after which the external modem automatically answers a call if any area is Perimeter Armed ...

Страница 127: ... If an event or group of events is to be routed to an SDI path the number entered in Primary Device determines which SDI path is used provided that RG Prim Primary SDI was set to Yes in Routing If events are to be routed to an IP address in a private LAN or WAN application determine which path is used Path 1 to Path 4 and enter the appropriate IP Address for that path refer to Path IP Add1 to Path...

Страница 128: ...med in Path Poll Rate is the interval at which the control panel sends a Heartbeat Event to the central station connected to the same network The value programmed in Path Ack Wait is the length of time the control panel waits for an acknowledgment of the Heartbeat Event If the acknowledgment is not received the control panel checks to determine if the Path Retry Count entry is greater than 0 If so...

Страница 129: ...low Path Poll Rate values of 1 to 4 the control panel interprets these entries as an entry of 5 5 minutes 300 seconds 1 hour 3600 seconds 12 hours 43 200 seconds 18 hours 64 800 seconds Path Ack Wait Default 13 Selection 0 5 seconds to 65535 seconds 0 The control panel does not look for any acknowledgment from the central station 5 to 65535 The control panel waits this amount of time to receive an...

Страница 130: ...ddresses two items parity and the number of stop bits for the network interface module NIM Pressing the SPACE bar on the D5200 toggles through the available options Set this item to No 1 when using the External Modem feature RTS Controll Default On Selection On AutoX Off AutoR On Sets RTS to on hardware control Auto X Automatically enables Xon Xoff software control Off Sets RTS off hardware contro...

Страница 131: ...mary destination twice and if unsuccessful tries the backup destination The control panel makes a total of ten attempts six to the primary four to the backup before generating a route group Comm Fail Event 6 8 Miscellaneous Fire Supv Res Type Default 0 Selection 0 1 2 0 The control panel sends a FIRE TROUBLE RESTORE when a Fire Supervision point restores to normal 1 The control panel sends a FIRE ...

Страница 132: ...econd pass code is not entered within the programmed time a Duress event is generated based on the first user code Duress reports mush be enabled in Routing in order to be sent to a central station Secondary Ambush Code Default Unique Selection Unique or any Unique The code used to end the timer must be different from the code used to disarm the area Any The timer can be stopped using a different ...

Страница 133: ...vate inside the Cross Point Window If a single Cross Point detects an alarm and stays faulted throughout the Cross Point Window a standard Alarm Report is generated for that point Conversely if a single Cross Point detects an alarm then restores and no other conditions occur an Unverified Event is generated for that point A second alarm on the first point does not create an Alarm Event but rather ...

Страница 134: ...D9412GV2 D7412GV2 Program Entry Guide 6 0 GV2AUX EN 134 Bosch Security Systems 5 05 F001U003636B Notes ...

Страница 135: ...ault Blank Selection Blank 1 to 8 1 to 8 Determines disarming rights The user s access level and the CC Scope determines which areas are disarmed Blank Only the area assigned to the D Entry Area disarms this door Enter the keypad number CC which determines the scope of the user ID s disarming rights Areas disarm on the basis of this keypad s scope and the authority level of the user D Custom Funct...

Страница 136: ... point type is required for the Door point you can use a Perimeter point type with a point response of 9 to C Also the debounce count must be set to 4 in Point Assignments When assigning Points 1 to 8 control panel zones the end of line EOL resistors must be removed from the control panel Also do not enable any POPIT points or OctoPOPIT points sharing the same point number as the Door point Failur...

Страница 137: ...door zone automatically upon a Fire Alarm This feature overrides a Secure Door state Locked Door state Auto Door and an Interlock Faulted point The relay activates for all doors with this prompt programmed as Yes when a Fire Alarm occurs in any area Relays that are activated by Fire Unlock can be returned to normal only through the keypad using the Door Control function This unlocks the door regar...

Страница 138: ... the opened door does not cause the point to enter into a trouble alarm or faulted condition D Buzz Time Default 2 seconds Selection Blank 1 second to 240 seconds Blank Buzz Time is not programmed for this door 1 to 240 The buzzer sounds for the amount of time programmed Enter the amount of time the buzzer output sounds to notify the user that the strike was activated and the door is ready to open...

Страница 139: ...Use this parameter when a user can open a door manually without relying on a token or card to activate the strike such as with a push bar When RTE Shunt Only is Yes RTE Events are not logged reported or printed D REXShunt Only Default No Selection Yes or No Yes Programmed shunt time activates so the door can be manually opened No REX automatically activates the programmed strike and shunt time Use...

Страница 140: ...tem determines if No Entry Events are sent to the control panel for processing memory printing and remote reporting A No Entry Event can be caused by Invalid or unknown user ID interlock or secured door or incorrect authority level RTE or REX for door in interlock or secured door D Enter Request Default No Selection Yes or No Yes A Door RTE Event from this door controller is sent to the control pa...

Страница 141: ...Chng Reports 20 Access Reports 20 Enhanced Routing 21 Programming a Duplicate Report 21 RG Primary SDI 22 RG Backup SDI 22 RG Primary Pager 22 Power Supervision 25 AC Fail Time 25 AC Fail Res Rpt 26 AC Tag Along 26 AC Battery Buzz 26 Bat Fail Res Rpt 26 Printer Parameters 27 Printer Address 27 P Area Assign 95 P Supervised 27 P Scope 27 P A1 through A8 in Scope 27 P Fire Events 28 P Burglar Event ...

Страница 142: ...r Assignment 45 Cmd Center 45 CC Supervised 46 CC Area Assign 46 CC Scope 46 CC A1 through A8 in Scope 47 CC Entr Key Rly 47 CC Entr Cycl Dr 47 CC Assign Door 48 CC Trouble Tone 48 CC Entry Tone 48 CC Exit Tone 49 CC Arm Now Warn 49 CC Close Door 49 CC EnhancCmdCtr 49 CC Passcode Follows Scope 40 CC Menu Key Lock 50 Area Text 50 Area 51 Area Is On 51 Area Not Ready 51 Area Is Off 51 Area Acct Is O...

Страница 143: ... L Unlock Door 64 L Secure Door 64 L Access Ctl Lvl 65 L Chg Display 65 L Chg Time Date 65 L Chg Passcode 65 L Add User 65 L Del User 66 L Extend Close 66 L View Log 66 L Print Log 66 L User Cmd 7 66 L User Cmd 9 66 L Bypass a Pt 66 L Unbypass a Pt 66 L Reset Sensors 66 L Change Relay 67 L Remote Program 67 L Move to Area 67 L Display Rev 67 L Service Walk 67 L Default Text 68 L Change Skeds 68 L ...

Страница 144: ... Responses 85 P Pt Response 86 P Entry Delay 87 P Ent Tone Off 87 P Silent Bell 87 P Ring Til Rst 87 P Audible After 2 Failures 88 P Invisible Pt 88 P Buzz On Fault 89 P Watch Point 89 P RlyResp Type 90 P Disp as Dvc 90 P Local While Disarmed 90 P Local While Armed 91 P Disable Rst 91 P FA Retrnable 91 P BP Retrnable 91 P Bypassable 92 P Swinger Byps 92 P Report Bypass at Occurrence 92 P Defer BP ...

Страница 145: ...ough 8 109 S Point Number 109 S Point Number 109 S Area 1 through 8 110 S Relay Number 110 S Relay Number 110 S Defer Test 111 S Hourly Report 111 S Defer Status 111 S Cmd Center 112 S Custom Func 112 S Cmd Center 1 through 8 113 S Access Ctl Level 113 S Access Ctl Level 113 S Door 1 through 8 114 S Door 1 through 8 114 S Door 1 through 8 114 S Door 1 through 8 115 S Door 1 through 8 115 S Door 1 ...

Страница 146: ...Rate 128 Path Ack Wait 129 Path Retry Count 129 SDI RPS Enhanced Communications Configuration 130 Baud Rate 130 Parity Stop 130 RTS Control 130 DTR Control 130 9133 Supervision 131 Base Port Number 131 Route Group Attempts 131 RG 1 Attempt 131 Miscellaneous 131 Fire Supv Res Type 131 Enable Protocol Type 131 Enable Anti Replay 131 Fire Trouble Resound 132 Early Ambush Timer 132 Secondary Ambush Co...

Страница 147: ...D9412GV2 D7412GV2 Program Entry Guide Programming Prompts Directory EN 147 Bosch Security Systems 5 05 F001U003636B Notes ...

Страница 148: ... 2005 Bosch Security Systems F001U003636B Bosch Security Systems 130 Perinton Parkway Fairport NY 14450 9199 Customer Service 800 289 0096 Technical Support 888 886 6189 ...