Bosch Security Systems | 5/05 | F001U003636B
RPS Reports
Selecting
Yes
enables sending a report when the RPS
Passcode Event occurs.
RPS Access Fail
can indicate a
wrong RPS passcode when
communicating with the control panel or a
valid RPS session was terminated by a
means other than a Good-bye or Reset-
bye command.
Remote Reset
indicates
a Reset-bye command issued from RPS,
Bad Call to RPS
indicates the
control panel called RPS but was unable
to connect.
Table 15: RPS Reports
Report Selections
Report
Description
R# Log
Threshold
Yes
, No
Event log threshold
reached
R# Log
Overflow
Yes
, No
Log is full, old events
are overwritten
R# Para
Changed
Yes
, No
RPS Parameter
Change Event
R# RPS OK
Yes
, No
Successful RPS
Access Event
R# RPS Fail
Yes
, No
Failed Access RPS
Event
R# Remote
Reset
Yes
, No
Remote Reset Event
R# Program
OK
Yes
, No
Successful Laptop
Access Event
R# Program
Fail
Yes
, No
Failed Laptop Access
Event
Point Reports
Selecting
Yes
enables a report to be sent when the
event occurs.
Table 16: Point Reports
Report Selections
Report
Description
R# Service Start
Yes
, No
Reorts Service
Walk Test Start
Event
R# Service End
Yes
, No
Service Walk
Test End Event
R# Fire Walk St
Yes
, No
Fire Walk Start
Event
R# Fire Walk End
Yes
, No
Fire Walk End
Event
R# Walk Test St
Yes
, No
Walk Test Start
Event for Walk
Test and Invisible
Walk Test
R# Walk Test End
Yes
, No
Walk Test End
Event for Walk
Test and Invisible
Walk Test
R# Extra Point
Yes,
No
Extra Point Event
R# Send Point
Text
∗
Yes
, No
Point Text
R# RF Low Bat
Yes,
No
Low battery
conditions for RF
points
R# RF Low Bat
Res
Yes,
No
Low battery
restoral
conditions for RF
points
∗
Point text is always transmitted when using
NetCom applications.
Содержание D7412GV2
Страница 1: ...EN Program Entry Guide Control Panels D9412GV2 D7412GV2 ...
Страница 76: ...D9412GV2 D7412GV2 Program Entry Guide 2 0 GV2MAIN EN 76 Bosch Security Systems 5 05 F001U003636B Notes ...
Страница 98: ...D9412GV2 D7412GV2 Program Entry Guide 4 0 RADXPNTS EN 98 Bosch Security Systems 5 05 F001U003636B Notes ...
Страница 134: ...D9412GV2 D7412GV2 Program Entry Guide 6 0 GV2AUX EN 134 Bosch Security Systems 5 05 F001U003636B Notes ...