D9412GV2/D7412GV2 |
Program Entry Guide | 5.0
RADXSKED
EN
| 100
Bosch Security Systems | 5/05 | F001U003636B
W# Monday
Default:
No
Selection:
Yes or No
W# Tuesday
Default:
No
Selection:
Yes or No
W# Wednesday
Default:
No
Selection:
Yes or No
W# Thursday
Default:
No
Selection:
Yes or No
W# Friday
Default:
No
Selection:
Yes or No
W# Saturday
Default:
No
Selection:
Yes or No
W# Open Early Begin
Default:
00:00
Selection:
HH:MM (hours and minutes)
00:00 to 23:59
Open Early Begin:
This program item is one of three
required to create an Opening Window. To finish
programming an Opening Window, Open Window
Start and Open Window Stop must be programmed.
The time programmed in the
W# Open Early Begin
field is the earliest time that the user is allowed to open
an area before the Opening Window Start time. If
Opening and Closing Reports are enabled, disarming
the area between midnight and the open Early Begin
time generates an Opening Report.
•
If
A# Disable O/C in Window
is set to
Yes
and
the area is disarmed between the Open Early
Begin time and the Open Window Start time, the
Opening event is sent with an Early to Open
modifier. If the Open Early Begin time is the same
as the Open Window Start time, no Opening
Event is sent.
•
If
Disable O/C in Window
is set to
No
and the
area is disarmed at any time, an Opening Event is
sent without an Early to Open or Late to Open
modifier.
Disarming the area between the Open Window Start
and open Window Stop times creates a local event in
the control panel event log, but does not send the
Opening Report to the central station.
Disarming the area between the Open Window Stop
time and before the next window’s Open Early Begin
time (or midnight, whichever is earlier) generates an
Opening Event with a Late to Open modifier.
When configuring multiple windows to operate on the
same day, ensure that they are added to the system in
chronological order. For example, if three windows are
programmed to execute on Tuesday, Window 1 (W1)
must occur before Window 2 (W2), and Window 2
must occur before Window 3 (W3).
Avoid programming the Open Early Begin
time before a time that is between another
window’s Open Window Start and Open
Window Stop times.
Do
not
program a window to cross the
midnight boundary.
Disabled windows have a blank beginning time. If the
entry for this prompt is blank, but times are
programmed for Open Window Start and Open
Window Stop, the window is disabled.
To disable the window, all hours and minutes spaces
must be blank.
Make time entries using a 24-hour clock.
For example:
Midnight is entered as 00:00
7:00 AM is entered as 07:00
2:45 PM is entered as 14:45
11:59 PM is entered as 23:59
Reboot the control panel to activate today’s window, if
the window needs to activate on the same day you
program it.
Содержание D7412GV2
Страница 1: ...EN Program Entry Guide Control Panels D9412GV2 D7412GV2 ...
Страница 76: ...D9412GV2 D7412GV2 Program Entry Guide 2 0 GV2MAIN EN 76 Bosch Security Systems 5 05 F001U003636B Notes ...
Страница 98: ...D9412GV2 D7412GV2 Program Entry Guide 4 0 RADXPNTS EN 98 Bosch Security Systems 5 05 F001U003636B Notes ...
Страница 134: ...D9412GV2 D7412GV2 Program Entry Guide 6 0 GV2AUX EN 134 Bosch Security Systems 5 05 F001U003636B Notes ...