D9412GV2/D7412GV2 |
Program Entry Guide | 2.0
GV2MAIN
EN
| 62
Bosch Security Systems | 5/05 | F001U003636B
L## Master Arm Delay
Default:
Refer to the program record sheet
Selection:
Blank or E
Function No.
Function Name
Alternate Keystroke
2 Master
Arm
Delay
[COMMAND][1]
Master arms areas based on the
CC# Scope
of the
keypad using an exit delay time.
When this item is accessed through the Function List,
Master Arm All allows the user to arm all areas
according to the authority level of the user and within
the
CC# Scope
of the keypad using an exit delay
time.
Arm Area arms only the area displayed. If
COMMAND 1 is used, it arms only the area where
the keypad is assigned.
L## Mstr Arm Inst
Default:
Refer to the program record sheet
Selection:
Blank or E
Function No.
Function Name
Alternate Keystroke
3 Master
Arm
Instant
[COMMAND][1][1]
This authority level permission allows a user to
execute the Master Arm Inst function. Refer to
Mstr
Arm Inst
on page55.
Arm Area arms only the area to which the keypad is
assigned.
If COMMAND 11 is used, it arms only the area where
the keypad is assigned.
Use COMMAND 11 carefully because all
Perimeter and Interior points become
Instant Armed.
L## Perim Instant
Default:
Refer to the program record sheet
Selection:
Blank or E
Function No.
Function Name
Alternate Keystroke
4 Perimeter
Instant
Arm
[COMMAND][2]
Instant arm all Perimeter points, including Delayed
points, only in the area where the keypad is assigned.
L## Perim Delay
Default:
Refer to the program record sheet
Selection:
Blank or E
Function No.
Function Name
Alternate Keystroke
5 Perimeter
Delay
Arm
[COMMAND][3]
Delay arm all Perimeter Delay point responses only in
the area where the keypad is assigned.
L## Watch Mode
Default:
Refer to the program record sheet
Selection:
Blank or E
Function No.
Function Name
Alternate Keystroke
6 Watch
Mode
[COMMAND][6]
Initiate the Watch Mode in the area to which this
keypad is assigned.
L## Perim Partial
Default:
Refer to the program record sheet
Selection:
Blank or E
Function No.
Function Name
Alternate Keystroke
7 Perimeter
Partial
Arm
[COMMAND][8]
Partially arms only the area where the keypad is
assigned.
This function ignores the
A# FA Bypass
Max
entry in Area Parameters.
Local Only Reporting:
No Closing Report
is sent to the central station, but a
Perimeter Delay Closing Event is generated
in the event log.
L## View Area Stat
Default:
Refer to the program record sheet
Selection: Blank or E
Function No.
Function Name
Alternate Keystroke
8
View Area Status
(Menu function only)
View the current arm or disarm status and the not
ready to arm status of all areas within the scope of the
keypad in this area. The user needs arming and
disarming authority.
Содержание D7412GV2
Страница 1: ...EN Program Entry Guide Control Panels D9412GV2 D7412GV2 ...
Страница 76: ...D9412GV2 D7412GV2 Program Entry Guide 2 0 GV2MAIN EN 76 Bosch Security Systems 5 05 F001U003636B Notes ...
Страница 98: ...D9412GV2 D7412GV2 Program Entry Guide 4 0 RADXPNTS EN 98 Bosch Security Systems 5 05 F001U003636B Notes ...
Страница 134: ...D9412GV2 D7412GV2 Program Entry Guide 6 0 GV2AUX EN 134 Bosch Security Systems 5 05 F001U003636B Notes ...