D9412GV2/D7412GV2 |
Program Entry Guide | 5.0
RADXSKED
EN
| 108
Bosch Security Systems | 5/05 | F001U003636B
5.1.3
Holiday Indexes for User Group Windows
You can enable up to four Holiday Indexes to use with
User Group Windows. Enable at least one Holiday
Index if
UW# Xept Holiday
is programmed as
Yes
for this user window, or if you want this window to
activate only on specific dates. Holidays are
programmed in Holiday Indexes. Refer to
Section 5.3
Holiday Indexes
on page 117 for programming
information.
UW# Xept Holiday
Default:
No
Selection:
Yes or No
Determine if the window is disabled on holidays, or is
active only on holidays. Use the instructions provided
in the
W# Xept Holiday
prompt in
Section 5.1.1
Opening and Closing
on page 99.
UW# Holiday 1 [through 4]
Default:
No
Selection:
Yes or No
Yes
The selected holiday index can be
used by users in the User Group
window.
No
The selected holiday index does not
apply to users in this User Group.
5.2 Skeds
Use the Skeds module to program the control panel to
automatically execute functions that are otherwise
started by the end user at the keypad. Each sked can
be programmed to occur at a specific time on a
specific date or day of the week. Up to 40 Skeds can
be programmed.
A sked can be edited from the keypad if
S## Time
Edit?
is
Yes
. The date and time can be changed using
the Change Sked function.
Each sked number can be programmed with one of 24
functions for the
S## Function Code
. In addition to
the function, a choice must be made as to what is
affected by the function. For example, when choosing
Function 2 (Disarm Sked), the disarming is the
function and the selected areas are what is affected.
The functions and their associated parameters are
listed in the Sked Function Code Table in the
D9412GV/D7412GV2 Program Record Sheet
(P/N: F01U003635), and they are explained in detail
following the
S## Function Code
prompt on page
109.
Each sked can be programmed with up to four
Holiday Indexes. The Holiday Indexes can execute
the sked on the holidays as well as on the date or
day(s) of the week, or, they can prevent the sked from
executing on the holidays (refer to
S## Xept Holiday
prompt in this section
).
Sked Number
Default:
1
Selection:
1 to 40
Enter the number of the sked you are programming.
S## TimeEdit
Default:
Yes
Selection:
Yes or No
Yes
The user can edit the time of this
sked from the keypad and determines
if this sked appears in the CHG
SKED display.
No
The user cannot edit the time of this
sked from the keypad and the sked
does not appear in the CHG SKED
display.
Select whether the user can edit the time of this sked
from the keypad.
Содержание D7412GV2
Страница 1: ...EN Program Entry Guide Control Panels D9412GV2 D7412GV2 ...
Страница 76: ...D9412GV2 D7412GV2 Program Entry Guide 2 0 GV2MAIN EN 76 Bosch Security Systems 5 05 F001U003636B Notes ...
Страница 98: ...D9412GV2 D7412GV2 Program Entry Guide 4 0 RADXPNTS EN 98 Bosch Security Systems 5 05 F001U003636B Notes ...
Страница 134: ...D9412GV2 D7412GV2 Program Entry Guide 6 0 GV2AUX EN 134 Bosch Security Systems 5 05 F001U003636B Notes ...