D9412GV2/D7412GV2 |
Program Entry Guide | 2.0
GV2MAIN
EN
| 18
Bosch Security Systems | 5/05 | F001U003636B
Table 12: Diagnostic Reports
Report Selections
Report
Description
R# SDI Dev
Fail
∗
Yes
, No
SDI device failure
R# SDI Dev
Restl
Yes
, No
Restoral of SDI
device failure
R# Watchdog
Rset
Yes
, No
Watchdog Reset
Event
R#
ParaChksmFail
Yes
, No
Parameter checksum
failure
R# Reboot
Yes
, No
Reboot Event
R# Ph Line
Fail
∗
Yes
, No
Failure of phone line
R# Ph Line
Rstl
Yes
, No
Restoral of phone
line after failure
R# AC Fail
∗
Yes
, No
Failure of AC power
to control panel
R# AC Restorl
Yes
, No
Restoral of AC
power to control
panel after failure
R# Batt
Missing
∗
Yes
, No
Battery Missing
Detection Event
R# Battery
Low
∗
Yes
, No
Low battery power
R# Battery Rstl
Yes
, No
Restoral of battery
power to control
panel after Missing or
Low Event
R# Rt Comm
Fail
∗
1
Yes
, No
Failure to send report
to specific route
R# Rt Comm
Rstl
Yes
, No
Restoral of
communication to
specific route after a
failure
R# Checksum
Fail
Yes
, No
Checksum Fail Event
R# Network
Fail
2
Yes,
No
Failure of network
R# Network
Rest
2
Yes,
No
Restoral of network
R# Network
Cond
2
Yes,
No
Condition of network
∗
Indicates an off-normal event.
1
This event covers Comm Fail Route Group and Comm
Fail Phone. If enabled, both events are sent; if disabled,
neither event is sent.
2
This event is reserved for future use.
Enable Rt Comm Fail and Rt Comm
Restore in only one route group.
Enable Rt Comm Fail and Rt Comm
Restore in only one route group.
Relay Reports
Selecting
Yes
enables sending a report when the event
occurs.
Table 13: Relay Reports
Report Selections
Report
Description
R# Sensor
Reset
Yes
, No
Sensor Reset Event
R# Relay Set
Yes
, No
Relay Set Event
R# Relay
Reset
Yes
, No
Relay Reset Event
When activating an on-board relay using
reomte automation software, the
D9412GV2 and D7412GV2 Control
Panels log and print the resulting event as:
Relay 250 (Relay A)
Relay 251 (Relay B)
Relay 252 (Relay C)
AutoFunc Reports
The following prompts support customized routing of
Auto Function Reports. Selecting
Yes
enables a report
to be sent when the event occurs.
Table 14: Auto-Function Reports
Report Selections
Report
Description
R# Sked
Executed
Yes
, No
Sked Executed Event
R# Sked
Changed
Yes
, No
Sked Changed Event
R# Execute
Fail
Yes
, No
Fail to Execute Event
Содержание D7412GV2
Страница 1: ...EN Program Entry Guide Control Panels D9412GV2 D7412GV2 ...
Страница 76: ...D9412GV2 D7412GV2 Program Entry Guide 2 0 GV2MAIN EN 76 Bosch Security Systems 5 05 F001U003636B Notes ...
Страница 98: ...D9412GV2 D7412GV2 Program Entry Guide 4 0 RADXPNTS EN 98 Bosch Security Systems 5 05 F001U003636B Notes ...
Страница 134: ...D9412GV2 D7412GV2 Program Entry Guide 6 0 GV2AUX EN 134 Bosch Security Systems 5 05 F001U003636B Notes ...