In a multi area system the following table shows area assignment and keypad indication of
zones:
Zone Number
Area
Indication keypad area 1
Indication keypad area 2
1
2
1
2
2
2
3
1
1
4
1
2
5
1
3
6
1
4
7
2
3
8
2
4
9
2
5
10
2
6
11
1
5
12
1
6
Outputs
Onboard / Extension Output
The alarm control panel is equipped with four on-board outputs and supports two DX3010
output extension modules with each extension module supporting 8 relay outputs, 20 outputs
in total.
When on-board output 1 or 2 fails due to a short circuit or open circuit, as long as there is a
backup power supply, the output fault will not affect the normal operation of the whole
system, but will be detected by the system.
Each output is programmable and can be set to follow multiple events.
Depending on the type of output event, the output parameters can be defined as area output
or follow zone alarm output. The output polarity of each output can be programmed and
defined as three modes: continuous output, pulse output or inverted.
The maximum time of each output is specified by programming and will be automatically reset
after expiration.
Electrical characteristics: 13.65VDC ± 3%. For PO-1+2, Max 750mA; PO+3+4, maximum
500mA.
Output Events
0 - Not Used
1 - Disarmed 0=all areas, 1-16 = Areas1-16
The output operates on below conditions:
1.
System disarmed after system reset
2.
System operated the disarm command
The output is reset:
1.
When the system is armed
2.
When the output programmed duration is up
7.3
7.3.1
7.3.2
58
en | Settings
AMAX panel 4000 / AMAX panel 4000
EN
2013.07 | 03 | F.01U.267.112
Installation Guide