A Fire zone does not send a restore report until the zone is restored.
10 - External Fault Zone
The Fault Zone/Input will perform as below:
1.
Disarm:
–
Zone normal - no Alarm / no report
–
Zone triggered - Fault / report
2.
AWAY Arm:
–
Zone normal - no Alarm / no report
–
Zone triggered - Alarm / report
–
Zone triggered - during exit time - Fault / report
–
Zone triggered - during entry time - Fault / report
3.
STAY Arm: Same as AWAY Arm performance.
–
The restore report will be sent when the zone is restored.
11 - Bolt Contact Zone
The Bolt-Contact zone will perform as below:
1.
Disarm:
–
Zone normal - no Alarm / no report
–
Zone triggered - no Alarm / no report
2.
AWAY Arm:
–
Zone normal - no Alarm / no report
–
Zone triggered - no Alarm / no report
–
Zone triggered - during exit time - no Alarm / no report
–
Zone triggered - during entry time - no Alarm / no report
3.
STAY Arm: Same as AWAY Arm performance.
–
This zone is mainly for prevention of arming (to ensure exit/entry door is locked
before arming the system and no alarm occurs when entering the premise through
the entry/exit door)
12 - Key Switch Toggle
If a zone is programmed as key-switch toggle, it will ignore all other programming items, such
as bypass, forcing arm. If the Zone Tamper function is enabled, the zone will process as zone
tamper. When a zone is programmed for key-switch arming then that zone is the input for a
momentary (toggle mode) keyswitch input. In toggle mode, every time the keyswitch input is
triggered the system will be armed.
Zone triggered: AWAY Arm
Zone normal: No effect
When the system is armed in this mode, the keypad activates two beeps and report sent is by
User Code 254.
13 - Key switch On / Off
If a zone is programmed as key-switch On/Off, it will ignore all other programming items, such
as bypass, forcing arm.If the Zone Tamper function is enabled, the zone will process as a zone
tamper. When a zone is programmed for key-switch arming then that zone is the input for a
On/Off keyswitch input. In On/Off mode, the control will arm when the zone is zone triggered
and disarm when it is normal. This zone allows the system to be armed or disarmed with an
on/off switch wired across the keyswitch zone.
Key-switch On/Off Zone activates no alarm event.
Zone triggered: Activate AWAY Arm.
AMAX panel 4000 / AMAX panel 4000
EN
Settings | en
51
Bosch Sicherheitsysteme GmbH
Installation Guide
2013.07 | 03 | F.01U.267.112