Programming
The control panel programming options are stored in a non-volatile flash memory. This
memory has all relevant configuration and user-specific data even after a total power loss.
Because the data retention time is quite long without power, reprogramming is not required
after powering up the control panel.
Programming with keypad is possible only when all of zones in the system are in disarmed
status and no alarm is activated. Installer Code is required for programming.
Notice!
It is not recommended to use other keypads or methods simultaneously to program the
system while programming with the current keypad.
Communication and Reports Setting
Report Options
Address
Default
Telephone Number / IP Address and Port for Receiver 1 0000 - 0016
15
Subscriber ID Number
0017 - 0022
000000
Transmission Format for Receiver (0 = Not used, 1 =
Contact ID, 2= SIA, 3 = Conettix IP)
0023
1
Anti-replay for Receiver (0 = Disabled, 1 = Enabled)
0024
1
EN=1
Acknowledge Wait Time for Receiver (05 - 99 seconds )
0025 - 0026
05
Network Polling Time for Receiver (001 - 999 minutes )
0027 - 0029
001
Telephone Number / IP Address and Port for Receiver 2 0030 - 0046
15
Subscriber ID Number
0047 - 0052
000000
Transmission Format for Receiver (0 = Not used, 1 =
Contact ID, 2= SIA, 3 = Conettix IP)
0053
1
Anti-replay for Receiver (0 = Disabled, 1 = Enabled)
0054
1
EN=1
Acknowledge Wait Time for Receiver (05 - 99 seconds )
0055 - 0056
05
Network Polling Time for Receive (001 - 999 minutes)
0057 - 0059
001
Telephone Number / IP Address and Port for Receiver 3 0060 - 0076
15
Subscriber ID Number
0077 - 0082
000000
Transmission Format for Receiver (0 = Not used, 1 =
Contact ID, 2= SIA, 3 = Conettix IP)
0083
1
Anti-replay for Receiver (0 = Disabled, 1 = Enabled)
0084
1
EN=1
Acknowledge Wait Time for Receiver (05 - 99 seconds)
0085 - 086
05
Network Polling Time for Receiver (001 - 999 minutes)
0087 - 089
001
Telephone Number / IP Address and Port for Receiver 4 0090 - 0106
15
Subscriber ID Number
0107 - 0112
000000
9