Refer to Section Keypad Indicators, page 20 to see how the zone is displayed during
exit time.
18 - Technical Alarm
The Technical Alarm zone will perform as below:
1.
Disarm:
–
Zone normal - no Alarm / no report
–
Zone triggered - Alarm / report
2.
AWAY Arm:
–
Zone normal - no Alarm / no report
–
Zone triggered - Alarm / report
–
Zone triggered - during exit time - Alarm / report
–
Zone triggered - during entry time - Alarm / report
3.
STAY Arm: Same as AWAY Arm performance.
–
A Technical zone does not send a restore report until the zone is restored.
19 - Reset
The Reset zone will perform as below:
1.
Disarm:
–
Zone normal - no Alarm / no report
–
Zone triggered – performs system reset / no report
2.
AWAY Arm:
–
Zone normal - no Alarm / no report
3.
STAY Arm: Same as AWAY Arm performance.
20 - Instant Report
The Instant report zone will perform as below:
1.
Disarm:
–
Zone normal - no Alarm / no restore report
–
Zone triggered - no Alarm / no report
2.
AWAY Arm:
–
Zone normal - no Alarm / no restore report
–
Zone triggered - no Alarm / sends report
–
Zone triggered - during exit time - Alarm / sends report
–
Zone triggered - during entry time - Alarm / sends report
3.
STAY Arm: Same as AWAY Arm performance.
Zone Function Settings / Zone Options
Zone Function Option
Description
Force Arm / Bypass
0
Disabled
1
Force Arm
2
Bypass
3
All
Silent Alarm / Chime
Mode
0
Disabled
1
Silent Alarm
7.2.3
AMAX panel 4000 / AMAX panel 4000
EN
Settings | en
53
Bosch Sicherheitsysteme GmbH
Installation Guide
2013.07 | 03 | F.01U.267.112