Event Record Count per Set/Unset Period
Option Event Record Count per Set/Unset Period defines the maximum number of records for
an event within the set/unset period.
System Tamper Indication In Area
Option System Tamper Indication In Area configures system where system tamper event is
indicated. System tamper indication can be assigned to either the area where Zone 1 is
located in or to all Areas.
Internal Siren Beep As Indication
Enables or disables Internal Siren Beep as Indication when the system is armed, disarmed or
programming mode is entered.
Battery Check Interval
Option Battery Check Interval defines the time interval in which the battery test is carried out.
Also battery test is carried out when armed or when system power up.
Cross Zone Timer
Option Cross Zone Timer defines time interval for the cross zone feature.
AC Power Supply Fault Report Delay
AC Power Supply Fault is reported with configurable delay time. Option AC Power Supply
Fault Report Delay defines delay time.
Date and Time
The alarm control panel has a 24-hour clock and a 12-month calendar that need to be set
during installation. The order is year, month, day, hour and minute, with each item occupying
two digits [YY] [MM] [DD] [HH] [MM].
For more information about date and time settings, see Date and Time Settings .
Fault Inquiry
Fault and tamper conditions
7.5.8
7.5.9
7.5.10
7.5.11
7.5.12
7.5.13
7.5.14
7.5.15
66
en | Settings
AMAX panel 4000 / AMAX panel 4000
EN
2013.07 | 03 | F.01U.267.112
Installation Guide
Bosch Sicherheitsysteme GmbH