Event Description
CID
SIA
ALL
Event
KP
Recall
Dialer
Event
EN
Event
RF RECEIVER JAM
1344
XQ
√
RF RECEIVER JAM RESTORE
3344
XH
√
RF RECEIVER CONFIGURATION CONFILICT
√
RF RECEIVER CONFIGURATION CONFILICT
RESTORE
√
RF POINT MISSING
1381
UY
√
RF POINT MISSING RESTORE
3381
UJ
√
RF POINT BATTERY FAULT
1384
XT
√
RF POINT BATTERY FAULT RESTORE
3384
XR
√
RF POINT FAULT
1380
BT
√
RF POINT FAULT RESTORE
3380
BJ
√
RF REPEATER MISSING
1382
UY
√
RF REPEATER MISSING RESTORE
3382
UJ
√
RF REPEATER BATTERY FAULT
1384
XT
√
RF REPEATER BATTERY FAULT RESTORE
3384
XR
√
RF REPEATER TAMPER
1383
XS
√
RF REPEATER TAMPER RESTORE
3383
XJ
√
RF REPEATER AC FAULT
1334
YP
√
RF REPEATER AC FAULT RESTORE
3334
YR
√
RF KEYFOB BATTERY FAULT
1384
XT
√
RF KEYFOB BATTERY FAULT RESTORE
3384
XR
√
RF KEYFOB PANIC ALARM
1120
PA
√
RF KEYFOB SILENT ALARM
1122
HA
√
RF CHANGE KEYFOB
√
FIRE UNVERIFIED
1378
FG
√
√
Receiver Network Programming Options
When the control panel transmits a report via network, the following options should be
programmed other than the IP Address and port:
Anti Reply
Anti-replay prevents unauthorized messages from being sent to the Central Monitoring Station
and being recognized as originating from the control panel.
Contact your central monitoring station for the correct setting.
Acknowledge Wait Time
7.1.4
AMAX panel 4000 / AMAX panel 4000
EN
Settings | en
37
Bosch Sicherheitsysteme GmbH
Installation Guide
2013.07 | 03 | F.01U.267.112
Содержание AMAX panel 4000
Страница 1: ...AMAX panel 4000 AMAX panel 4000 EN ICP AMAX4 P1 ICP AMAX4 P2 EN ICP AMAX P3 EN en Installation Guide ...
Страница 2: ......