Programming with the ICP-EZPK Programming Key
The ICP-EZPK Programming Key allows you to save or copy programming information from
your control panel. After saving information in the programming key, you can easily program
other AMAX panel 4000 / AMAX panel 4000 EN with the same programming data. You can also
use the programming key to back up existing information.
If you have a new programming key, enter installer’s programming mode, program the system
as required, and connect the programming key to the control panel.
To connect the programming key:
Locate the socket labelled PROGRAMMING KEY at the top of the printed circuit board (PCB).
Observe the triangular markings on the PCB and align them with the markings on the
programming key.
For example: to copy data from the control panel to the programming key:
1.
Enter the installer code (the default is 1234) + (958) and press [#] to enter into installer’s
programming mode.
2.
Enter [9 6 2 #]. Refer to Section 6.23 Command 962 – Copy the control panel memory to
the programming key, page 46.
3.
Enter [9 6 0 #] to exit from installer’s programming mode.
4.
The system resets and returns to the disarmed state. And the programming key becomes
your standard data pattern for future control panel programming.
!
Caution!
If you do not enter installer’s programming mode first, which connects the blank ICP-EZPK
Programming Key (blue) to the control panel, no data can be uploaded /downloaded.
An unknown error may be caused if the installer’s programming mode is not exited before
removing the programming key.
Programming Key
With the programming key, the programming parameters of the current alarm control panel to
other systems with the same applications.
Copying Parameters of the Alarm Control Panel to Key
Copy the programming data in the memory of the alarm control panel into the programming
key with the keypad.
1.
Connect the programming key to the plug marked as "PROGRAMMING KEY" on the top of
the printed circuit board (PCB) of the alarm control panel. Please note that the direction
of the programming key should be consistent with the direction marked on the PCB.
2.
Select text keypad installation menu [ADDRESS/KEY PROGR – COPY DATA TO KEY] and
Press [#]. After successfully copying the programming data of the alarm control panel to
the programming key, the confirmation tone will be sounded. Wrong prompt tone and
display of [Failure of Control Panel Parameters to Key] indicate damage of programming
key data. The data need to be copied into the programming key again.
3.
Unplug the programming key from the alarm control panel.
4.
LED/Icon LCD keypad can also be used to copy alarm control panel parameters to key
parameters. See Command 962.
Copying Key Parameters to the Alarm Control Panel
Copy the programming data of the programming key into the alarm center.
8.7
AMAX panel 4000 / AMAX panel 4000
EN
Configuration | en 105
Bosch Sicherheitsysteme GmbH
Installation Guide
2013.07 | 03 | F.01U.267.112