When no more zones (with cross zone option) are triggered within the cross zone time,
no alarm is created.
–
When the first zone is triggered twice or more within the cross zone time, no alarm is
created.
–
When a second zone or further zones (with cross zone option) is/are triggered within the
cross zone time, then an alarm is created for all triggered zones.
–
When the first zone or one of the other zones (with cross zone option) is/are triggered
twice or more after cross zone time is expired, the timer restarts.
Unverified Alarm Report
Enables/disables option Unverified Alarm Report. When a cross zone is triggered, but no alarm
is created, system creates an unverified alarm in order to report. System reports unverified
alarms if option Unverified Alarm Report is enabled.
Adding and Changing Zone
Based on zone numbers, when adding or changing each zone, it is required to specify its area,
select the zone functions and select the module of zone source.
When the zone is selected to 0, i.e., the zone is not used, any addresses set on the zone
function and module selection are invalid.
Zone Indication Keypad and Event Log
Zones may be indicated on keypads and in event logs with a number that are different from
zone number used for programming and hardware input.
One area system
Zones are indicated on keypads according to the zone numbers. When disable one zone the
indication number of all following (higher) zone numbers will shift to a value decreased by
one.
Multi area system
Only zones assigned to one area are indicated on an area keypad in the order beginning with 1
and by following the order of zone numbers.
Examples:
In a one are system keypad zone number 17 should be indicated on a 16 zone LED keypad.
After disabling zone 16 (or another one in range 1 to 16) zone number 17 is indicated on
keypad as number 16.
7.2.4
7.2.5
AMAX panel 4000 / AMAX panel 4000