Site Requirements & Prerequisites
2-1
Chapter 2
Installation and Setup
2.1 Introduction
MT1000A is delivered completely assembled. It is designed for operation as a
desktop unit or for mounting in a 19-inch rack. For instructions of rack mounting,
refer to the
Rack Mounting Kit for 19 inch Racks
guide that comes with the RM kit.
Mechanical and electrical installation procedures for MT1000A are provided in the
following sections.
After installing the unit, refer to
Chapter 3
for operating instructions and system
configuration procedures.
In case a problem is encountered, refer to
Chapter 5
for test and diagnostics
instructions.
No internal settings, adjustment, maintenance, or repairs may be performed
by either the operator or the user; such activities may be performed only by a
skilled technician who is aware of the hazards involved.
Always observe standard safety precautions during installation, operation, and
maintenance of this product.
2.2
Site Requirements & Prerequisites
Power
AC/DC-powered MT1000A units should be installed within 1.5m (5 feet) of an
easily accessible grounded AC outlet capable of furnishing a supply voltage in the
range of 100 to 240 VAC or 40–72 VDC.
DC-powered MT1000A units require a 24 VDC power source.
Tributary Connections
Each MT1000A tributary interface has one RJ-45 connector.
Appendix A
provides
the pin allocation for the RJ-45 connector.
The maximum allowable line attenuation between each tributary port and the
user's equipment is 12 dB.