MT1000A
Installation and Operation Manual
Appendix A Interface Specifications
MNG-ETH Connector
A-3
A.3 Control Connector
The optional MT1000A supervisory port has a standard RS-232 DTE interface. The
physical interface is a 9-pin female connector, designated CONTROL. Connector
wiring is given in
Table A-2
.
Table A-2. CONTROL DTE Connector, Pin Functions
Pin Line Direction
Remarks
1 Data Carrier Detect (DCD) To MT1000A
2 Receive Data (RD)
To MT1000A
3 Transmit Data (TD)
From MT1000A
4 Data Terminal Ready (DTR) From MT1000A
5 Signal Ground (SIG)
Common signal reference and DC power supply ground
6 Data Set Ready (DSR)
To MT1000A
(Not used)
7 Request to Send (RTS)
From MT1000A
8 Clear to Send (CTS)
To MT1000A
9 Ring Indicator (RI)
To MT1000A
(Not used)
A.4 MNG-ETH Connector
One LAN Ethernet RJ-45 connector is mounted on the MNG-ETH module. The
pinout is shown in
Table A-3
.
Table A-3. Ethernet RJ-45 Connector Pin Assignment
Pin Designation
Function
Direction
1
RX+
Receive – positive lead
Input
2
RX-
Receive – negative lead Input
3
TX+
Transmit – positive lead Output
6
TX-
Transmit – negative lead Output
4, 5, 7, 8 -
Not connected
-
Содержание MT1000A-13-R3
Страница 2: ......
Страница 16: ...Chapter 1 Introduction MT1000A Installation and Operation Manual 1 10 Technical Specifications...
Страница 28: ...Chapter 3 Operation MT1000A Installation and Operation Manual 3 4 Turning MT1000A Off...
Страница 72: ...Appendix B MT1000A MIBs MT1000A Installation and Operation Manual B 2...