MT1000A
Installation and Operation Manual
Chapter 4 Configuration
Configuring the MT1000A
4-13
MT1000A
Port Alarms
Source Name Num Severity Status
Local P-2 Rx AIS 23 MINOR ON
Local P-3 Signal Loss 21 MAJOR ON
>
ESC-prev.menu; !-main menu; &-exit 1 user(s)
Figure 4-17. Port Alarms Screen
The Port Alarms screen only displays alarms that are currently triggered. Alarms
that are currently in the OFF status (not activated) are not displayed.
The MT1000A port alarms are described in
Chapter 5
.
4.7 Configuring
the
MT1000A
The use of a terminal enables you to:
•
View the configuration of the E1 and E2 interfaces, to identify whether the
interfaces are in the normal mode or in the looped mode
•
Set local loop connections in the local MT1000A at both E1 and E2 interfaces
•
Set local loop connections in the remote MT1000A at both E1 and E2
interfaces
•
Set the redundancy mode of the E2 interface
•
Set the E1 remote loopback connection
•
Reset MT1000A to the default configuration (removing loops and switching to
the normal redundancy mode)
Configuring redundancy
To configure the redundancy between the local and remote devices:
1. From the Main Menu (
Figure 4-2
), choose
Configuration
.
The Configuration menu (
Figure 4-18
) is displayed.