MT1000A
Installation and Operation Manual
Chapter 5 Testing and Diagnostics
List of Alarms and Events
5-3
5.3
List of Alarms and Events
The MT1000A alarms are described in Table 5-2.
Table 5-2. MT1000A System Alarms
Message on terminal
Description
Severity
CDP fail
A failure has occurred in
the CDP.
Major
FLASH problem
A problem occurred in the
device FLASH device.
Could not save user
configuration.
Major
PS1 FAIL
Power supply A has failed. Major
PS2 FAIL
Power supply B has failed. Major
Redundancy not available
Unable to activate
redundancy between the
uplinks. This alarm occurs
only if the redundancy
mode is set to AUTO or
MANUAL.
Major
Remote alarm-DAIS
Received a Demux AIS.
Major
Remote connection FAIL
A managment connection
could not be established
with the remote device.
Major
Table 5-3. MT1000A Port and Up-Link Alarms
Message on terminal
Description
Severity
ETH Integrity fail
The managment port is
not connected.
Major
Incorrect Tributary Freq
There is a problem with
the tributary frequency.
Major
Looped
Loop detected on the
uplinks.
Major
Loss of frame
Loss of frames on the
uplinks.
Major
Rx AIS
Received AIS on the
uplinks or the channels.
Minor
Signal Loss
Signal loss detected on
uplinks or channels.
Major