Chapter 4 Configuration
Configuring the MT1000A
4-15
MT1000A
Local Redundancy
1. Force Link (Link A)
2. Redundancy Mode > (Auto)
Please select item <1 to 2>
ESC-prev.menu; !-main menu; &-exit 1 user(s)
Figure 4-21. Local Redundancy Menu
5. Choose the link for which you want to set redundancy. Choose
Force Link
to
toggle the selected Main Link between
Link A
and
Link B
.
6. Choose
Redundancy Mode
to set the mode to use.
The Redundancy Mode menu (
Figure 4-22
) is displayed.
MT1000A
Redundancy mode (Auto)
1. Auto
2. Manual
3. Off
Please select item <1 to 3>
ESC-prev.menu; !-main menu; &-exit 1 user(s)
Figure 4-22. Redundancy Mode Menu
7. Choose the redundancy mode you want to use:
Auto
—When the selected Main Link (for example, Link A) fails,
MT1000A will automatically switch over to the backup Main Link (for
example, Link B)
Manual
—When the selected Force Link fails, the system switches to the
backup link. The backup link remains in use, even if the Force Link returns
to service.
Off
—Turns off redundancy. When the selected Main Link fails,
MT1000A will not change over to the backup Main Link.
This completes the setup of redundancy for the local device.
8. To configure redundancy for the remote MT1000A, from the Redundancy
menu (
Figure 4-20
), choose
Remote Redundancy
.
The Remote Redundancy menu appears. This menu is identical to the
Local Redundancy menu (
Figure 4-21
).
9. To configure the remote redundancy, refer to the above procedure describing
how to configure local redundancy.
You can set the mode for the remote device, which will then perform redundancy
according to the status of its links.
Note