MT1000A
Installation and Operation Manual
Chapter 4 Configuration
Monitoring the Physical Ports
4-9
MT1000A
Management Ethernet Status
Link Integrity (No integrity)
>
ESC-prev.menu; !-main menu; &-exit 1 user(s)
Figure 4-10. Ethernet Status Screen
The Link Integrity can be one of the following:
•
OK—The Ethernet cable has integrity
•
No integrity—The Ethernet cable is not connected or some other problem
exists.
Monitoring the Status of the Up-Link
To monitor the status of the up-link:
•
From the Local/Remote Physical Port Status menu (
Figure 4-9
), choose
Up-Link Status
.
The Up-link Status screen (
Figure 4-11
) is displayed.
MT1000A
Up-Link Status
Link A type > (Fiber optic)
Link A status > (No alarm)
Uplink A mode > (Multi mode)
Transmitter type Link A > (Laser)
Wave length Link A > (1550 nm)
Connector type Link A > (ST)
Link B type > (Fiber optic)
Link B status > (Signal loss)
Uplink B mode > (Multi mode)
Transmitter type Link B > (Laser)
Wavelength Link B > (1550 nm)
Connector type Link B > (ST)
>
ESC-prev.menu; !-main menu; &-exit 1 user(s)
Figure 4-11. Up-Link Status Screen
Monitoring the Status of the Channel Port
To monitor the status of the channel port:
•
From the Local/Remote Physical Port Status menu (
Figure 4-9
), choose
Channels Status
.
The Channel Port Status screen
(Figure 4-12
) is displayed.