Chapter 5 Testing and Diagnostics
MT1000A
Installation and Operation Manual
5-4 Diagnostic
Tests
The MT1000A events are described in Table 5-4.
Table 5-4. MT1000A Events
Event Description
BUFFER OVERFLOW
The log file overran the last events.
LOGIN SWITCH ON
User changed access name.
PASSWORD SWITCH ON
User changes access password.
SW DOWNLOAD FAIL
Software download failed.
SW DOWNLOAD OFF
Software download process finished.
SW DOWNLOAD ON
Software download is in process.
Uplink switch A->B
Switched from uplink A to uplink B – reason unknown.
Uplink switch A->B:LOOPED Switched from uplink A to uplink B – loop detected in uplink A.
Uplink switch A->B:LOSS
Switched from uplink A to uplink B – LOSS in uplink A.
Uplink switch A->B:OOF
Switched from uplink A to uplink B – out of frames in uplink A.
Uplink switch A->B:USER
Switched from uplink A to uplink B – user request.
Uplink switch B->A
Switched from uplink B to uplink A – reason unknown.
Uplink switch B->A:LOOPED Switched from uplink B to uplink A – loop detected in uplink B.
Uplink switch B->A:LOSS
Switched from uplink B to uplink A – LOSS in uplink B.
Uplink switch B->A:OOF
Switched from uplink B to uplink A – out of frames in uplink B.
Uplink switch B->A:USER
Switched from uplink B to uplink A – user request.
5.4 Diagnostic
Tests
MT1000A supports the following types of loopback connections:
•
Loopbacks toward the local MT1000A
•
Loopbacks toward the remote MT1000A.
The test functions are controlled by the management software. During all
loopbacks, the TST indicator lights up on the units that participate in the loopback
path.
The available loopback functions are described in the following paragraphs.