MT1000A
Installation and Operation Manual
Chapter 4 Configuration
Alarms 4-11
Clearing the System Log File
To remove all entries from the log file:
1. From the System Monitoring menu (
Figure 4-5
), choose
Clear Log File
.
A confirmation message appears.
2. Press
Y
to erase the log file.
4.6 Alarms
MT1000A detects fault conditions and initiates alarms and events to alert the user:
•
Alarms
(major and minor) have two statuses: ON and OFF. The alarm status
automatically changes to OFF when a fault condition that triggered the alarm is
cleared.
•
Events
have only ON status.
Displaying System Alarms
To display the system alarms:
•
From the System Monitoring menu (
Figure 4-5
), choose
Local System Alarms
or
Remote System Alarms
.
The Local System Alarms screen (
Figure 4-14
) or Remote System Alarms
screen is displayed. The Remote System Alarms screen is similar to the
Local System Alarms screen.
MT1000A
Local System Alarms
Source Name Num Severity
Status
1. Local DEV PS2 FAIL 2 MAJOR ON
2. Local DEV Remote alarm-DAIS 6 MAJOR ON
>
Please select item <1 to 2>
ESC-prev.menu; !-main menu; &-exit 1 user(s)
Figure 4-14. Local System Alarms Screen
The Local/Remote System Alarms screen only displays alarms that are currently
triggered. Alarms that are currently in the OFF status (not activated) are not
displayed.
The MT1000A system alarms are described in
Chapter 5
.