39
3.
Press the key to select
Slave
or
Master
.
Use the keys to select between the
two options. Select
Master
to set the power supply as a
master
, or select
Slave
to set
the power supply as a
slave
. Always set the
Slave
supplies first and
Master
supply last.
4.
Press the key to select
Addr…
. Press
and the display will prompt to enter an
address. Use the numeric keypad to enter an
Address
, which must be different than all
other power supplies that you want to connect together in parallel. Enter any number
between 0
–
31.
5.
Press
to save the changes.
6.
Exit the menu by pressing
several times.
3.5
Program Sequence Mode (List mode)
Note: Internal List mode functionality is not available on model 9117
List mode functionality is only available in the software program for model 9117.
The power supply (models 9115/B(-AT) and 9116/B only) has a list mode feature that allows
storing programmed sequences into internal non-volatile memory and recalling and running
them per configured parameters. A total of 10 steps can be configured for each sequence, and
a total of 10 sequences are available for storage. Additionally, multiple sequences or all 10
sequences can be saved into a program configuration, where each program configuration allows
running one sequence after another. This allows for a total maximum of 100 steps in one
program configuration. Up to 10 program configurations can be saved and recalled to and from
the non-volatile memory. Below is an illustration of how programmed sequences are
structured, stored, and recalled.