23
5.
Press or to confirm the selection and to display the aliquots
6.
Select the desired number of aliquots with
7.
Press or to confirm selection
8.
Select the desired dispensing pace with (0.1 - 9.9 seconds)
9.
Press to confirm the selection and to display the speed in
or
press and continue from Step 14.
10. Select the speed in with (1= Min to 9 = Max)
11. Press or to confirm selection and to display the speed out
12. Select the speed out with (1= Min to 9 = Max)
13. Press or to confirm selections
14. Position the tip to aspirate and press the START button . The display
shows PRE OUT and arrow down to indicate the reset function.
15. Position the tip to discard priming excess and press the START
button .
16. To dispense, position the tip, press the START button once and the
pipettor dispenses the aliquots at the specified pace.
17. Finally position the tip to discard any remaining excess and press the
START button twice .
Step 14 Step 15 Step 16
Step 17
Note: It is possible to stop the second counter and interrupt dispensing at any
time by pressing the START button. Releasing the START button activates the
counter again and dispensing continues.
Note: It is also possible to interrupt the dispensing by pressing the START
button and then ENTER key simultaneously. The display will show E and the tip
can be emptied by pressing the START button.
▲
▼
▼
▼