Plexus 9000 Installation and Operations Manual
System Specifications
Section 130-115-000
Issue 6, April 25, 2003
Telica, Inc.
4-3
4.1.4 Power
The Plexus requires redundant -48 Vdc power feeds. Refer to
for power specifications.
Table 4-D. Plexus 9000 POWER SPECIFICATIONS
Requirement
With DS-1/DS-3
With Octal DS-3
Input voltage
-40 Vdc to –56.7 Vdc
-40 Vdc to –56.7 Vdc
Thermal output
*
up to 2730 BTUs /hr/shelf
up to 4505 BTUs /hr/shelf
Current draw
*
20 Amperes per shelf
33 Amperes per shelf
Power consumption
*
800 Watts
1320 Watts
*
Fully loaded at 40 Vdc.
T11-B
4.1.5 Interfaces
The Plexus 9000 can have DS-1, DS-3/STS-1, Voice Server, Network or
Packet Access I/O modules (IOMs). Refer to the following tables for
IOM specifications.
•
for framing and line codes
•
for DS1 IOM specifications
•
for J1 IOM specifications
•
for E1 IOM specifications
•
for DS3 IOM specifications
•
for STS-1 specifications
•
for OC-3/STM-1 specifications
•
for OC-12/STM-4 specifications
•
for single-mode optical ENA specifications
•
for multi-mode optical ENA specifications