Passwords by default expire after 90 days. However there is a grace
period with a default of 7 days. During this period, you can log in but
must change your password before executing any other commands. A
user cannot change passwords more frequently than every 20 days and the
current and previous five passwords cannot be reused. The preceding
parameters can also be changed with the ED/ENT-USER-SECU
command. These restrictions do not apply to changes made by a user with
ADMIN privileges.
Table 5.3-E. Plexus 9000 Access Levels
Level Description
ADMIN
Administrative permits the user to perform all TL1
commands including managing user accounts or profiles
and downloading new software.
SW
SoftWare permits the user to issue COPY-MEM and
RTRV commands so the user can download new software.
SA
Service Affecting access level permits the user to perform
all TL1 commands except security commands
(ENT/ED/DLT-USER-SEC)
NSA
Non-Service Affecting permits the user to only issue
SCHED and RTRV commands to schedule and view the
Plexus 9000’s status and statistics information.
VIEW
View permits the user to only issue RTRV commands to
view the Plexus 9000’s status and statistics information.
63-A
When using Telnet, twenty users (different user names) can be logged into
the Plexus 9000 (i.e., TL1 craft and 19 Telnet sessions). If another user
tries to log in, he will be denied access. If a user has not used the
keyboard for a specified period, has exited the Telnet session, he will be
logged out.
The System Fault Manager receives and records event and fault
notifications related to physical and logical system state changes. It
provides a readable log format to the TL1 agent upon request. It provides
the interface to replication services to allow log replication on protected
SP.
Craft Interfaces
There are two craft interfaces located on the front of the SP module. One
is a DB-9 RS-232 interface and the other is an RJ-45 Ethernet interface.