![Belfort AWOS Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/belfort/awos/awos_maintenance-manual_2725781008.webp)
-5-
BELFORT
INSTRUMENT
Proprietary Information
3.0
M
AINTENANCE
P
ROGRAM
O
VERVIEW
Belfort AWOS maintenance consists of preventive and corrective maintenance activities.
Preventive maintenance consists of tri-annual and annual maintenance tasks required to keep the
Belfort AWOS system in peak operational condition. Corrective maintenance utilizes the Built-
In Test (BIT) features of the Belfort AWOS software to identify system faults and minimize
troubleshooting activities. For sensor troubleshooting, removal instructions and procedures refer
to section 6.0 of this manual. Refer to the Belfort AWOS Installation and Checkout manual for
installation instructions and checkout of replaced sensors and components.
A suite of system diagnostic self-tests is continuously running and automatically outputs system
status to a history file every time sensor information is transmitted from the DCP. If the self-test
detects a problem, the suspected sensor or function is identified in the system status log with an
error flag.
When routine maintenance tasks and adjustments are not adequate to correct system errors or
problems, defective components must be replaced. Site maintenance personnel must not attempt
to repair defective system LRU components.
Figure 1
Typical Display Acquisition Terminal Unit setup
4.0
Q
UALIFICATION
R
EQUIREMENTS FOR
M
AINTENANCE
P
ERSONNEL
– Installation and
maintenance of the Belfort AWOS system must be performed by qualified personnel. FAA
Order 6700.20A contains the qualification requirements for maintenance personnel who
maintain Non-Federal facilities. Installation and maintenance personnel must meet the
requirements of FAA Order 6700.20A and have the special knowledge and skills needed to
install and maintain a Belfort AWOS facility. These skills can be obtained by completing the
“Belfort AWOS Installation and Maintenance Training Program” course and successfully
Содержание AWOS
Страница 17: ... 14 BELFORT INSTRUMENT Proprietary Information Figure 2a Securing the Tower for Maintenance ...
Страница 49: ... 46 BELFORT INSTRUMENT Proprietary Information Figure 9 Temperature Humidity Sensor Removal ...
Страница 51: ... 48 BELFORT INSTRUMENT Proprietary Information Figure 10 Visibility Sensor Removal ...
Страница 60: ...BELFORT INSTRUMENT Proprietary Information Appendix A Belfort AWOS Maintenance Forms ...
Страница 66: ...BELFORT INSTRUMENT Proprietary Information This page intentionally left blank ...
Страница 71: ...BELFORT INSTRUMENT Proprietary Information Appendix B Belfort AWOS Tri Annual Annual 5 Year Maintenance Plan ...
Страница 74: ...BELFORT INSTRUMENT Proprietary Information Appendix C UHF Transceiver Specifications ...
Страница 76: ...BELFORT INSTRUMENT Proprietary Information Appendix D Standard Unicom Radio ICOM A110 VHF Radio Specifications ...
Страница 88: ...BELFORT INSTRUMENT Proprietary Information Appendix F DCP Site Configuration Procedure ...
Страница 93: ...BELFORT INSTRUMENT Proprietary Information Appendix G Belfort AWOS Atomic Clock Verification Procedure ...