![Belfort AWOS Скачать руководство пользователя страница 54](http://html1.mh-extra.com/html/belfort/awos/awos_maintenance-manual_2725781054.webp)
-51-
BELFORT
INSTRUMENT
Proprietary Information
10.5 W
IND
D
IRECTION
S
ENSOR AND
V
ANE
R
EMOVAL
I
NSTRUCTIONS
SAFETY PRECAUTIONS
1. Do not perform outdoor Belfort AWOS maintenance tasks during a thunderstorm.
2. Use extreme caution when lowering the tilt-over tower whenever ice or snow has accumulated
on the tower cross arm or the sensors. The extra weight may cause the tower to fall over
rapidly.
TOOLS & PARTS REQUIRED
1.
Three (3) M4 x 8, Socket head screws
2.
3 mm Allen wrench
3.
Socket wrench and 3/16” socket
4.
Small flat blade screw driver.
Removal Procedures: Refer to figure 9.
1.
At the DATU display terminal, issue a NOTAM advisory to alert users that the Belfort
AWOS system is being serviced prior to beginning investigation of this fault. The
NOTAM to be issued is "
Belfort AWOS system being serviced, do not use current
weather data outputs
." Verify that this NOTAM advisory is displayed on the operator
screen prior to beginning this maintenance tasks. Refer to the "Belfort AWOS Operator
Manual" for instructions on how to enter and delete NOTAMs.
2.
Remove tower-securing bolts and tilt the tower until the cross arm is at a comfortable
working height to access the Wind Direction Sensor. Secure the tower in that position by
tying the attached tower hold-down rope to the base of the Belfort AWOS tower as shown
in Figure 2.
3. Power down the power enclosure by opening the AC and DC circuit breakers.
4. If the wind direction vane only needs to be replaced go to step 13.
5.
Remove the three (3) hole plugs in the bottom of the cross arm that cover the mounting
screw access holes.
6. Remove the mounting screws.
7. Disconnect the wind direction sensor from the Cross Arm.
8. Loosen and disconnect the wind direction connector from the mating connector.
9.
Inspect the sensor cable and connector for damage, corrosion or bent or broken pins.
Replace damaged cable if needed.
10.
Contact Belfort Instrument Co. customer support to make arrangements for replacement of
defective components.
11.
Refer to the Belfort AWOS Installation and Checkout Manual Section 9.0 for installation
and checkout of the replacement parts.
12.
Document sensor replacement on the FAA form 6030-1.
13.
Care should be taken to not move the red direction pointer.
14.
Position the direction vane with rubber band as shown in Figure 4. Follow Section 5.6
steps 6 thru 12 to verify and if necessary, correct the proper vane alignment with the red
pointer.
Содержание AWOS
Страница 17: ... 14 BELFORT INSTRUMENT Proprietary Information Figure 2a Securing the Tower for Maintenance ...
Страница 49: ... 46 BELFORT INSTRUMENT Proprietary Information Figure 9 Temperature Humidity Sensor Removal ...
Страница 51: ... 48 BELFORT INSTRUMENT Proprietary Information Figure 10 Visibility Sensor Removal ...
Страница 60: ...BELFORT INSTRUMENT Proprietary Information Appendix A Belfort AWOS Maintenance Forms ...
Страница 66: ...BELFORT INSTRUMENT Proprietary Information This page intentionally left blank ...
Страница 71: ...BELFORT INSTRUMENT Proprietary Information Appendix B Belfort AWOS Tri Annual Annual 5 Year Maintenance Plan ...
Страница 74: ...BELFORT INSTRUMENT Proprietary Information Appendix C UHF Transceiver Specifications ...
Страница 76: ...BELFORT INSTRUMENT Proprietary Information Appendix D Standard Unicom Radio ICOM A110 VHF Radio Specifications ...
Страница 88: ...BELFORT INSTRUMENT Proprietary Information Appendix F DCP Site Configuration Procedure ...
Страница 93: ...BELFORT INSTRUMENT Proprietary Information Appendix G Belfort AWOS Atomic Clock Verification Procedure ...